以瑞安市某污水厂为例,进行工艺介绍及运行数据分析,总结出多模式A2/O氧化沟工艺在实际运行过程中遇到的问题之一是除总磷效果不理想,并尝试通过改进工艺找出改善途径,最终取得了满意的效果。
Taking a wastewater treatment plant,in Ruian City as example,technological introduction and operation data analysis have been made. One of the problems encountered in the multi-mode A^2/O oxidation ditch process in actual running is that the removing result of total phosphorus isn't good. Better ways having been tried for improvement, satisfactory results are finally obtained.