Sysmex XE-2100血细胞分析仪白细胞分类计数的性能评价 被引量:3

Performance Evaluation of Leukocyte Differential Count with Sysmex XE-2100 Automated Hematology Analyzer
下载PDF
导出
摘要 目的对SysmexX E-2100血细胞分析仪白细胞分类计数进行性能评价。方法从不精密度、可比性、临床诊断敏感性这三个方面对Sysmex XE-2100血细胞分析仪白细胞分类计数进行评价。结果该仪器的批内、短期和长期不精密度分别在0.91%~15.53%之间。白细胞分类计数仪器法与人工显微镜法比较,中性粒细胞、淋巴细胞、单核细胞、嗜酸性粒细胞、嗜碱性粒细胞的相关系数(r^2)分别是0.9564,0.9418,0.7007,0.9313和0.8111。200份临床病例类型与仪器白细胞分类结果比较,各类白细胞的临床符合率分别在5%~100%之间。结论Sysmex XE-2100血细胞分析仪白细胞分类计数具有较高精密度及临床诊断敏感度,与人工显微镜分类有较好的相关性等特点,它可作为一种过筛手段进行初检。 Objective To evaluate the performance of leukocyte differential count with Sysmex XE-2100 automated hematology analyzer. Methods According to H20-A standard approved by National Committee for Clinical Laboratory Standards (NCCLS/CLSI), the performance of leucocyte differential count was evaluated from imprecision, comparability and clinical determination of sensitivity. Results The within-run,short-term and long-term imprecision of the instrument were between 0.91%-15.53%. Compared with the manual microscopy classification, the correlation coefficient( r^2 ) of neutrophil, lymphocyte,monocyte,eosinophil and basophil were 0. 956 4,0. 941 8,0. 700 7,0. 931 3 and 0. 811 1 respectively. The clinical determination of sensitivity to finding of abnormal samples were between 50% - 100% in 200 clinical cases. Conclusion Sysmex XE-2100 automated hematology analyzer had good clinical determination of sensitivity, low imprecision and fine correlation with manual microscopy classification. It is suitable for the initial screening of clinical diseases.
出处 《现代检验医学杂志》 CAS 2012年第3期123-124,127,128,共4页 Journal of Modern Laboratory Medicine
关键词 SYSMEX XE-2100 白细胞分类计数 评价 sysmex XE-2100 leukocyte differential count evaluation
  • 相关文献

参考文献4

二级参考文献5

  • 1孙芾,王厚芳,于俊峰,穆煜,柳杰,杜振波.血细胞显微镜复检标准的制定及临床应用[J].中华检验医学杂志,2005,28(2):155-157. 被引量:128
  • 2National Committee for Clinical Laboratory Standards. Reference leukocyte differential count (proportional) and evaluation of instrument methods: approved standard. NCCLS Document H20-A [S].NCCLS, Wayne (USA), 1992.
  • 3中华人民共和国卫生部.中华人民共和国卫生行业标准-白细胞分类计数参考方法.北京:人民卫生出版社,2005-12-01.
  • 4陈先荣.EDTA依赖性血小板假性减少形成与抗凝时间的关联[J].中华实用医药杂志,2006,6:112-114.
  • 5Barnes PW, McFadden SL, Machin SJ, et al. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis. Lab Hematol, 2005, 11:83-90.

共引文献25

同被引文献22

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部