期刊文献+

外置式MBR和NF系统运行参数及膜污染控制技术改进 被引量:4

Improving of Operating Parameters and Membrane Pollution Control Technology of External MBR and NF System
下载PDF
导出
摘要 针对北京阿苏卫垃圾卫生填埋场渗沥液处理设备,即MBR和NF设备运行过程中的一些控制参数和传统的膜污染控制技术进行现场记录和分析,并对相关运行参数进行研究和控制,经扩容改造后阿苏卫垃圾卫生填埋场渗沥液工程采用膜污染控制技术,从而使设备稳定运行,最大程度地增加回收率,提高了系统的处理效率。 Some control parameters and traditional membrane pollution control technology in the operation of MBR and NF equipment in Asuwei Waste Sanitary Landfill Site were noted on spot and analyzed, and the related operating parameters were studied and controlled. The membrane pollution control technology was used in the leachate expansion renovation project of Asuwei Waste Sanitary Landfill Site, in order to operate equipment steadily, gain the highest recovery, and improve treating efficiency of the system.
出处 《环境卫生工程》 2012年第5期39-43,共5页 Environmental Sanitation Engineering
关键词 渗沥液 膜污染 运行参数 回收率 技术改进 leachate membrane pollution operating parameter recovery technological improvement