期刊文献+

Electrocatalytic Oxidation and Simultaneous Determination of Uric Acid,Xanthine,Hypoxanthine and Dopamine Based on β-Cyclodextrin Modified Glassy Carbon Electrode 被引量:2

Electrocatalytic Oxidation and Simultaneous Determination of Uric Acid,Xanthine,Hypoxanthine and Dopamine Based on β-Cyclodextrin Modified Glassy Carbon Electrode
下载PDF
导出
摘要 A novel covalently modified glassy carbon electrode with β-cyclodextrin was prepared via electropolymerization technique for the simultaneous determination of uric acid(UA),xanthine(XA),hypoxanthine(HX) and dopamine(DA).This new electrode presented an excellent electrocatalytic activity towards the oxidation of UA,XA,HX and DA by cyclic voltammetry(CV) method.The oxidation peaks of the four compounds were well defined and had the enhanced peak currents.The separation potentials of the oxidation peaks for DA-UA,UA-XA and XA-HX were 150,390 and 360 mV in CV,respectively.By means of differential pulse voltammetry(DPV) method,the calibration curves in the ranges of 10―225,5―105,10―170 and 5―150 μmol/L were obtained for UA,XA,HX and DA,respectively.The lowest detection limits(S/N=3) were 5,1.25,5 and 1.5 μmol/L for UA,XA,HX and DA,respectively.The practical application of the modified electrode was demonstrated by the determination of DA in hydrochloride injection and UA,XA,HX in human urine samples. A novel covalently modified glassy carbon electrode with β-cyclodextrin was prepared via electropolymerization technique for the simultaneous determination of uric acid(UA),xanthine(XA),hypoxanthine(HX) and dopamine(DA).This new electrode presented an excellent electrocatalytic activity towards the oxidation of UA,XA,HX and DA by cyclic voltammetry(CV) method.The oxidation peaks of the four compounds were well defined and had the enhanced peak currents.The separation potentials of the oxidation peaks for DA-UA,UA-XA and XA-HX were 150,390 and 360 mV in CV,respectively.By means of differential pulse voltammetry(DPV) method,the calibration curves in the ranges of 10―225,5―105,10―170 and 5―150 μmol/L were obtained for UA,XA,HX and DA,respectively.The lowest detection limits(S/N=3) were 5,1.25,5 and 1.5 μmol/L for UA,XA,HX and DA,respectively.The practical application of the modified electrode was demonstrated by the determination of DA in hydrochloride injection and UA,XA,HX in human urine samples.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第6期1047-1053,共7页 高等学校化学研究(英文版)
基金 Supported by the Natural Science Foundation of Jilin Province,China(No.20090326)
关键词 Β-CYCLODEXTRIN Uric acid XANTHINE HYPOXANTHINE DOPAMINE β-Cyclodextrin Uric acid Xanthine Hypoxanthine Dopamine
  • 相关文献

参考文献41

  • 1Park G., Adams R. N., Anal Lett., 1972, 5, 887.
  • 2Martin C., Chem. Br., 1998, 34, 40.
  • 3West E. S., Todd W. R., Mason H., Bruggen J. T. V., Text Book of Biochemistry, Fourth Ed., Oxoford & 1BH Publishing Co., New Delhi, 1996.
  • 4Bhagavan N. V., Medical Biochemistry, Fourth Ed., Academic Press, USA, 2002.
  • 5Dutt J. S. N., Cardosi M. F., Davis J., Analyst, 2003, 128, 811.
  • 6Mateos F. A., Puig J. G., Jimenez M. L., Fox I. H., J. Clin. Invest., 1987, 79, 847.
  • 7Hall A. P., Barry P. E., Dawber T. R., McNamara P. M., Am. J. Med., 1947, 42, 27.
  • 8Guilbault G. G., Analytical Uses of Immobilized Enzymes, Marcel Dekker, New York, 1984.
  • 9Sumi S., Kidouchi K., Ohba S., Wada Y., J. Chromatogr. B, 1995, 670, 376.
  • 10Yamamoto T., Moriwaki Y., Takahashi S., Wada Y., J. Chromatogr. B, 1996, 681,395.

同被引文献8

  • 1汪振辉,张卉.嵌入式超薄碳糊膜电极伏安法同时测定黄嘌呤和次黄嘌呤[J].分析化学,2005,33(5):671-674. 被引量:8
  • 2LENGHOR N, JAKMUNEE J, VILEN M, et al. Se- quential injection redox or acid-base titration for deter- mination of ascorbic acid[J]. Talanta, 2002,58(6): 1139-1144.
  • 3FOTSING L, FILLET M, BECHET I, et al. Deter- mination of six water-soluble vitamins in a pharmaceu-tical formulation by capillary electrophoresis[J]. Jour- nal of Pharmaceutical and Biomedical Analysis, 1997, 15(8):1113-1123.
  • 4KANDAR R, DRABKOVA P, HAMPL R. The de- termination of ascorbic acid and uric acid in human se minal plasma using an HPLC with UV detection[J]. J Chromatogr B, 2011,879(26) :2834 2839.
  • 5WUWei-che, CHANG Han-wei, TSAI Yuchen. Electrocatalytic detection of dopamine in the presence of ascorbic acid and uric acid at silicon carbide coated electrodes[J]. Chemical Communications, 2011, 47 (22) :6458 6460.
  • 6PAIXAO T R L C, BERTOTTI M. FIA determina- tion of ascorbic acid at low potential using a ruthenium oxide hexacyano ferrate modified carbon electrode[J]. J Pharm Biomed Anal, 2008,46(3) : 528-533.
  • 7AMBROSI A, MORRIN A, SMYTH M R, et al. The application of conducting polymer nanoparticle e- lectrodes to the sensing of ascorbic acid[J]. Anal Chim Acta, 2008,609(1) :37-43.
  • 8ZHENG Long-zhen, WU Shou-guo, LIN Xiang-qin, et al. Preparation and characterization of a novel cy- clodextrin modified poly (N-acetylaniline) film [J]. Macromolecules, 2002,35 (16) : 6174-6177.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部