Near-infrared fundus camera based on polarization switch in stray light elimination 被引量:2

Near-infrared fundus camera based on polarization switch in stray light elimination
原文传递
导出
摘要 This letter shows that the human eye fundus tissue has higher reflectivity at the near-infrared (NIR) wavelength, and that some aberrations exist at the pre-optical system from cornea to vitreous. We design a NIR fundus camera with inner focusing, which can be applied to the -10 D to 10 D range of vision and has the advantage of ensuring the stability of image when is focused. Considered as Liou's eye aberration model, we correct the integrated aberration to ensure a 100 lp/mm resolution when we complete the assembly and calibration of the fundus camera. Kohler illumination is also applied to obtain uniform fundus illumination. Moreover, we put forward a novel method for stray light elimination based on polarization switch, which inhibits ghost image formation near the focal plane when the illumination beam is reflected by the eyepiece surface. The result shows that this method is effective in ensuring an illumination uniformity of 80%, with the advantage of simple structure and easy assembly. This letter shows that the human eye fundus tissue has higher reflectivity at the near-infrared (NIR) wavelength, and that some aberrations exist at the pre-optical system from cornea to vitreous. We design a NIR fundus camera with inner focusing, which can be applied to the -10 D to 10 D range of vision and has the advantage of ensuring the stability of image when is focused. Considered as Liou's eye aberration model, we correct the integrated aberration to ensure a 100 lp/mm resolution when we complete the assembly and calibration of the fundus camera. Kohler illumination is also applied to obtain uniform fundus illumination. Moreover, we put forward a novel method for stray light elimination based on polarization switch, which inhibits ghost image formation near the focal plane when the illumination beam is reflected by the eyepiece surface. The result shows that this method is effective in ensuring an illumination uniformity of 80%, with the advantage of simple structure and easy assembly.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第3期56-59,共4页 中国光学快报(英文版)
基金 supported by the National Natural Science Foundation of China(Nos.60977008and60678048) the National Ministry Education Fund for Doctoral of China(No.20103219110014) the Chinese Academy of Sciences Key Laboratory Fund(No.2008DP173445)
  • 相关文献

参考文献11

  • 1M. Hammer and D. Schweitzer, Phys. Med. Biol. 47, 179 (2002).
  • 2F. C. Delori and K. P. Pflibsen, Appl. Opt. 28, 1061 (J989).
  • 3E. DeHoog and J. Schwiegerling, Appl. Opt. 47, 6769 (2008).
  • 4E. DeHoog and J. Schwiegerling, Appl. Opt. 48, 221 (2009).
  • 5N. Kishida and S. Ono, "Eye fundus examination appa- ratus" US Patent 7055955 (2006).
  • 6N. Ichikawa and S. Ono, "Fundus camera" US Patent 7219996 (2007).
  • 7C. Li, Q. Sun, Y. Liu, Q. Lu, J. Wang, J. Sun, J. Liu, and F. Qu, Chin. J. Opt. Appl. Opt. (in Chinese) 3, 363 (2010).
  • 8Z. Wang and Y. Xu, Opt. Precis. Eng. (in Chinese) 16, 1567 (2008).
  • 9Y. Xu, Z. Wang, and Y. Tian, Acta Photon. Sin. (in Chinese) 38, 1122 (2009) .
  • 10Y. Zhang, G. Zhao, X. Zhang, and Y. Gu, Opt. Precis. Eng. (in Chinese) 17, 1014 (2009).

同被引文献14

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部