摘要 本试验采用RRLC-Q-TOF-MS对非法添加11种PDE5抑制剂进行定性和定量检验。化合物准分子离子峰的保留时间、一级质谱和二级质谱定性;一级质谱准分子离子峰面积定量。本方法定性准确,干扰少,而且可对同分异构体进行区分。定量结果线性关系良好,11种PDE5抑制剂线性相关系数(r)均在0.99以上。样品中检出他达拉非10.6mg/粒。 The purpose of this study is to develop a qualitative and quantitative analysis method of illegally added 11 PDE.5 inhibitors in healthy foods by RRLC-Q-TOF-MS. The qualitative analysis is based on the retention time,ms spectrometer and ms/ms spectrometer. The quantitative analysis is base on the quasi-molecular ion peak areas of 11 PDE5 inhibitors. This method is accurate, less interference, and the isomers can be distinguished with this method. The linear relationship between the quantitative results was well, and the related coetficients are all above 0.99. The sample was detected illegally added tadalafil 10.6mg per capsule.
作者 王自
出处 《临床合理用药杂志》 2013年第17期44-46,共3页 Chinese Journal of Clinical Rational Drug Use
关键词 RRLC-Q-TOF-MS PDE5抑制剂 非法添加 RRLC-Q-TOF-MS PDE5 inhibitors Ulegally added
  • 相关文献

参考文献5

二级参考文献40

  • 1雷灼雨,罗萍,周渝南.补肾壮阳药中非法加入西药“枸橼酸西地那非”的检出方法[J].中国药品标准,2005,6(5):61-62. 被引量:12
  • 2PENG Z, SHARON S Y, PEILING H, etal. Simultaneous determination of synthetic phosphodiesterase-5 inhibitors found in a dietary supplement and pre-mixed bulk powders for dietary supplements using high-performance liquid chromatography with diode array detection and liquid chromatography-electrosp ray ionization tandem mass spectrometry[J]. J Chromatogr A, 2006, 1 104: 113-122.
  • 3STARK S , SACHASE R , STARK A, et al. Erectile response on visual sexual stimulation after 20 mg or 40 rag Bay 38-9456 or placebo[J]. Eur Urol, 2000, 37 (S2): 15-18.
  • 4Cordy RB, Laramee JA, Durst HD. Versatile new ion source for the analysis of materials in open air under ambient conditions. Anal Chem,2005 ,77 ( 8 ) :297.
  • 5Haeflige OP, Jeckehnann N. Direct mass spectrometric analysis of flavors and fragrances in real applications using DART. Rapid Commun Mass Spectrom,2007 ,21 (8):1361.
  • 6Schurek J, Vaclavik L, Hooijerink HD, et al. Control of strobilurin fungicides in wheat using direct analysis in real time accurate time - of - flight and desorption electrospray ionization linear ion trap mass spectrometry. Anal Chem,2008,80 (24) :9567.
  • 7Kim HJ,Jang YP. Direct analysis of curcumin in turmeric by DARTMS. Phytochem Anal,2009,20(5) :372.
  • 8Corbin JD,Francis SH.Cyclic GMP phosphodiesterase-5:target of sildenafil[J].J Biol Chem,1999,274:13729-13732.
  • 9Lue TF.Erectile dysfunction[J].N Engl J Med,2000,342:1802-1813.
  • 10Foster DC,Wedel BJ,Robinson SW,et al.Mechanisms of regulation and functions of guanylyl cyclascs[J].Rev Physiol Biochem Pharmacol,1999,135:1-39.