Control for Modified University of Cape Town Process Using Oxidation-Reduction Potential in the Second Anoxic Zone

Control for Modified University of Cape Town Process Using Oxidation-Reduction Potential in the Second Anoxic Zone
下载PDF
导出
摘要 The aim of this work is to evaluate the feasibility of applying the technology of oxidation-reduction potential (ORP) control on the municipal wastewater treatment system for nitrogen and phosphorus removal. Meanwhile the relation between the optimal ORP ( ORPopt ) and influent C/N ratio was evaluated, in which the influent chemical oxygen demand ( COD ) concentration was stabilized at (290 ± 10 ) mg/L, the influent total phosphorus (TP) concentration was stabilized at (7.0 ± 0.5 ) mg/L. The results indicated that: (1) the ORP in the second anoxic zone had effect on nitrogen and phosphorus removal capability, and the average percentages of phosphorus uptake in ANO2 zone ( ηa ) increased with increasing ORP, i. e. , increasing from 12. 0% at - 143 mV to 22.0%,30.0%,37.0%, and45.0% at -123, -111, -105 and -95 mV, respectively; (2) the ORPopt as function of influent C/N ratio could be calculated by the equation: y ffi 252. 73e〈 -x/3.39) _ 131.01 ; the maximum percentage of phosphorus uptake in ANO2 as function of the ORPopt could be calculated by the equation: y ffi -0.49e(x/15.58) + 1. 51. The ORPopt was the important process control parameter that must be optimized for operation of enhanced biological phosphorus removal ( EBPR ) system. Moreover, ORP sensor is very simple, and the industrial applications of this strategy is practical. The aim of this work is to evaluate the feasibility of applying the technology of oxidation-reduction potential(ORP)control on the municipal wastewater treatment system for nitrogen and phosphorus removal.Meanwhile the relation between the optimal ORP(ORP opt)and influent C/N ratio was evaluated,in which the influent chemical oxygen demand(COD)concentration was stabilized at(290±10)mg/L,the influent total phosphorus(TP)concentration was stabilized at(7.0±0.5)mg/L.The results indicated that:(1)the ORP in the second anoxic zone had effect on nitrogen and phosphorus removal capability,and the average percentages of phosphorus uptake in ANO2zone(ηa)increased with increasing ORP,i.e.,increasing from 12.0%at-143 mV to22.0%,30.0%,37.0%,and 45.0%at-123,-111,-105 and-95 mV,respectively;(2)the ORP opt as function of influent C/N ratio could be calculated by the equation:y=252.73e(-x/3.39)-131.01;the maximum percentage of phosphorus uptake in ANO2as function of the ORP opt could be calculated by the equation:y=-0.49 e(x/15.58)+1.51.The ORP opt was the important process control parameter that must be optimized for operation of enhanced biological phosphorus removal(EBPR)system.Moreover,ORP sensor is very simple,and the industrial applications of this strategy is practical.
出处 《Journal of Donghua University(English Edition)》 EI CAS 2013年第3期215-221,共7页 东华大学学报(英文版)
基金 National Natural Science Foundation of China(NSFC)(No.50978118)
关键词 modified University of Cape Town (MUCT) process NITRATE oxidation-reduction potential (ORP) phosphorus uptake 氧化还原电位 过程控制参数 缺氧区 开普敦 污水处理系统 大学 修改 脱氮除磷
  • 相关文献

参考文献3

二级参考文献59

共引文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部