期刊文献+

Semen analysis standardization: is there any problem in Polish laboratories? 被引量:5

Semen analysis standardization: is there any problem in Polish laboratories?
下载PDF
导出
摘要 The aim of the study was to determine the degree of compliance of Polish laboratories with World Health Organization (WHO) recommendations, with regard to semen analysis methodology. A survey requesting information about methods of semen analysis was distributed to employees of 55 laboratories. Respondents who had participated in external seminological workshops (31%) were termed certified respondents (CR), the remaining (69%)--non-certified respondents (NCR). Only one laboratory (6%) in the CR group and none in the NCR were compliant with WHO guidelines for methods and equipment used to evaluate seminal volume, sperm motility, concentration, vitality and morphology. Most problems were of volume measurement (weighing method was reported by 17% of CR and 10% of NCR) and staining method for sperm morphology (Papanicolau or Diff-Quik were found in 33% of CR and 23% of NCR). A three- or four-point grading of sperm motility was used by the majority of respondents; however, 17% of CR and 37% of NCR did not use a laboratory counter to tally spermatozoa. Although a haemocytometer method was used by 80% of laboratories in each group, the improved Neubauer chamber was used only by 42% of CR and 19% of NCR. In each group, 24% of laboratories did not perform a vitality test. Procedural errors and the interchangeable utilization of two or even three methods to analyse a given parameter was observed in both groups. The results indicate a need for standardisation of the methods and continuous, unified training in semen analysis in Polish laboratories. The aim of the study was to determine the degree of compliance of Polish laboratories with World Health Organization (WHO) recommendations, with regard to semen analysis methodology. A survey requesting information about methods of semen analysis was distributed to employees of 55 laboratories. Respondents who had participated in external seminological workshops (31%) were termed certified respondents (CR), the remaining (69%)--non-certified respondents (NCR). Only one laboratory (6%) in the CR group and none in the NCR were compliant with WHO guidelines for methods and equipment used to evaluate seminal volume, sperm motility, concentration, vitality and morphology. Most problems were of volume measurement (weighing method was reported by 17% of CR and 10% of NCR) and staining method for sperm morphology (Papanicolau or Diff-Quik were found in 33% of CR and 23% of NCR). A three- or four-point grading of sperm motility was used by the majority of respondents; however, 17% of CR and 37% of NCR did not use a laboratory counter to tally spermatozoa. Although a haemocytometer method was used by 80% of laboratories in each group, the improved Neubauer chamber was used only by 42% of CR and 19% of NCR. In each group, 24% of laboratories did not perform a vitality test. Procedural errors and the interchangeable utilization of two or even three methods to analyse a given parameter was observed in both groups. The results indicate a need for standardisation of the methods and continuous, unified training in semen analysis in Polish laboratories.
出处 《Asian Journal of Andrology》 SCIE CAS CSCD 2013年第5期616-621,共6页 亚洲男性学杂志(英文版)
关键词 clinical laboratory COMPLIANCE semen analysis World Health Organization clinical laboratory compliance semen analysis World Health Organization
  • 相关文献

参考文献8

二级参考文献54

  • 1J.Erenpreiss,M.Spano,J.Erenpreisa,M.Bungum,A.Giwercman.Sperm chromatin structure and male fertility:biological and clinical aspects[J].Asian Journal of Andrology,2006,8(1):11-29. 被引量:46
  • 2Burnett D.Understanding Accreditation in Laboratory Medicine.London:ACB Venture Publications; 1996.
  • 3Whitehead TP,Browning DM,Gregory A.A comparative survey of the results of analyses of blood serum in clinical chemistry laboratories in the United Kingdom.J Clin Pathol 1973; 26:435-45.
  • 4Bullock DG,Wilde CE.External quality assessment of urinary pregnancy oestrogen assay:further experience in the United Kingdom.Ann Clin Biochem 1985; 22:273-82.
  • 5World Health Organisation.WHO Laboratory Manual for the Examination of Human Semen and Sperm-Cervical Mucus Interaction,1st edn.Singapore:Press Concern; 1980.
  • 6World Health Organisation.WHO Laboratory Manual for the Examination of Human Semen and Sperm-Cervical Mucus Interaction,2nd edn.Cambridge:Cambridge University Press; 1987.p67.
  • 7World Health Organisation.WHO Laboratory Manual for the Examination of Human Semen and Sperm-Cervical Mucus Interaction,3rd edn.Cambridge:Cambridge University Press; 1992.pi 07.
  • 8Neuwinger J,Bejre H,Nieschlag E.External quality control in the andrology laboratory:an experimental multicenter trial.Fertil Steril 1990; 54:308-14.
  • 9Matson PL.External quality assessment for semen analysis and sperm antibody detection:results of a pilot scheme.Hum Reprod 1995; 10:620-5.
  • 10Cooper TG,Atkinson A,Nieschlag E.Experience with external quality control in spermatology.Hum Reprod 1999; 14:765-9.

共引文献83

同被引文献31

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部