期刊文献+

TEMPO/STA法与Baird-Parker平板计数法测定食品中金黄色葡萄球菌的比较研究 被引量:4

Reliability Comparison of TEMPO/STA Method with Baird-Parker Method for the Determination of Staphylococcus aureusin Foods
下载PDF
导出
摘要 使用TEMPO/STA法和Baird-Parker平板计数法对速冻食品、生鲜乳、肉制品、冷食菜和调味品5类共150组样品进行金黄色葡萄球菌加标实验,结果表明两种方法检测结果符合率高达94.67%,并且检测结果P值均大于0.05,无显著性差异。同时使用TEMPO/STA法和Baird-Parker平板计数法对冷食菜、调味品、糕点、方便食品、生鲜乳、速冻食品和生肉7类共300组自然样品进行检测验证,结果显示两种方法的金黄色葡萄球菌检出率分别为33.33%和31.33%,对阳性结果进行统计学分析发现两种方法无显著性差异。 In this study, TEMPO/STA method and Baird-Parker method in the Chinese national standard GB 4789.10—2010 were used to count Staphylococcus aureus in 150 samples from five kinds of foods including quickfrozen foods, raw milk, meat products, cold fish products and condiments. The results showed that there were good coincidence rate as high as 94.67% and the P value was larger than 0.05, suggesting that no significant difference between the two methods. The positive rates of Staphylococcus aureus with TEMPO/STA method and Baird-Parker method were 33.33% and 31.33%, respectively in 300 natural samples assigned to 7 groups including cold dish, condiment, pastry, convenient foods, raw milk, frozen foods and raw meat. Statistical analysis showed no significant difference between the two methods.
出处 《食品科学》 EI CAS CSCD 北大核心 2013年第20期246-249,共4页 Food Science
关键词 TEMPO STA法 Baird-Parker平板计数法 金黄色葡萄球菌 食品 TEMPO/STA method Baird-Parker method Staphylococcus aureus food
  • 相关文献

参考文献11

二级参考文献105

共引文献90

同被引文献44

  • 1H.Zhang1,2, S.Li3, X.H.Wang 4, Q.Li1,2, S.H.Wei3, L.Y.Gao4, W.P.Zhao1,2, Z.G.Hu1, R.S.Mao1, H.S.Xu1, H.Y.Cai 4, Y.Y.Yue3, G.Q.Xiao1 1Institute of Modern Physics, CAS, Lanzhou 730000, China 2 Key Laboratory of Heavy Ion Radiation Medicine of Gansu Province, Lanzhou 730000, China 3 The General Hospital of Lanzhou Command, Lanzhou 730050, China 4 Tumor Hospital of Gansu Province, Lanzhou 730050, China.Results of Carbon Ion Radiotherapy for Skin Carcinomas in 33 Patients[J].生物物理学报,2009,25(S1):415-416. 被引量:45
  • 2胡秀杰,张相萍,包小兵.金黄色葡萄球菌增菌培养基增菌效果观察[J].医药论坛杂志,2005,26(18):3-3. 被引量:4
  • 3张琳,李敏,于莉,孟云,韩北忠.食品中金黄色葡萄球菌检测方法的比较研究[J].食品工业科技,2006,27(6):166-169. 被引量:16
  • 4焦振泉,郭云昌,裴晓燕,刘秀梅.食源性致病菌检测方法研究进展——Ⅰ.传统检测方法[J].中国食品卫生杂志,2007,19(1):58-62. 被引量:20
  • 5Wang J. Electrochemical glucose biosensors [J]. Chem Rev, 2008, 108(2): 815-825.
  • 6Newman J D, Turner A P. Home blood glucose biosensors: a commercial perspective [J]. Biosens Bioelectron, 2005, 20(12): 2435-2453.
  • 7Xiang Yu, Lu Yi. Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets [J]. Nat Chem, 2011, 3: 673-703.
  • 8Xiang Yu, Lu Yi. Portable and quantitative detection of protein biomarkers and small molecular toxins using antibodies and ubiquitous Personal Glucose Meters [J]. Anal Chem, 2012, 84: 4174-4178.
  • 9Xiang Yu, Lu Yi. Using commercially available Personal Glu- cose meters for portable quantification of DNA [J]. Anal Chem, 2012, 84: 1975-1980.
  • 10Xiang Yu, Lu Yi. An invasive DNA approach toward a generalmethod for portable quantification of metal ions using a personal Glucose meter[J]. Chem Commun, 2013, 49: 585-587.