期刊文献+

Excitation and Detection of Shear Horizontal Waves with Electromagnetic Acoustic Transducers for Nondestructive Testing of Plates 被引量:13

Excitation and Detection of Shear Horizontal Waves with Electromagnetic Acoustic Transducers for Nondestructive Testing of Plates
下载PDF
导出
摘要 The fundamental shear horizontal(SH0) wave has several unique features that are attractive for long-range nondestructive testing(NDT). By a careful design of the geometric configuration, electromagnetic acoustic transducers(EMATs) have the capability to generate a wide range of guided wave modes, such as Lamb waves and shear-horizontal(SH) waves in plates. However, the performance of EMATs is influenced by their parameters. To evaluate the performance of periodic permanent magnet(PPM) EMATs, a distributed-line-source model is developed to calculate the angular acoustic field cross-section in the far-field. Numerical analysis is conducted to investigate the performance of such EMATs with different geometric parameters, such as period and number of magnet arrays, and inner and outer coil widths. Such parameters have a great influence on the directivity of the generated SH0 waves that arises mainly in the amplitude and width of both main and side lobes. According to the numerical analysis, these parameters are optimized to obtain better directivity. Optimized PPM EMATs are designed and used for NDT of strip plates. Experimental results show that the lateral boundary of the strip plate has no perceivable influence on SHO-wave propagation, thus validating their used in NDT. The proposed model predicts the radiation pattern ofPPM EMATs, and can be used for their parameter optimization. The fundamental shear horizontal(SH0) wave has several unique features that are attractive for long-range nondestructive testing(NDT). By a careful design of the geometric configuration, electromagnetic acoustic transducers(EMATs) have the capability to generate a wide range of guided wave modes, such as Lamb waves and shear-horizontal(SH) waves in plates. However, the performance of EMATs is influenced by their parameters. To evaluate the performance of periodic permanent magnet(PPM) EMATs, a distributed-line-source model is developed to calculate the angular acoustic field cross-section in the far-field. Numerical analysis is conducted to investigate the performance of such EMATs with different geometric parameters, such as period and number of magnet arrays, and inner and outer coil widths. Such parameters have a great influence on the directivity of the generated SH0 waves that arises mainly in the amplitude and width of both main and side lobes. According to the numerical analysis, these parameters are optimized to obtain better directivity. Optimized PPM EMATs are designed and used for NDT of strip plates. Experimental results show that the lateral boundary of the strip plate has no perceivable influence on SHO-wave propagation, thus validating their used in NDT. The proposed model predicts the radiation pattern ofPPM EMATs, and can be used for their parameter optimization.
出处 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2014年第2期428-436,共9页 中国机械工程学报(英文版)
基金 supported by National Natural Science Foundation of China(Grant Nos.51075012,10772008) Beijing Municipal Natural Science Foundation of China(Grant No.1122005)
关键词 electromagnetic acoustic transducers shear-horizontal waves strip plate nondestructive testing electromagnetic acoustic transducers, shear-horizontal waves, strip plate, nondestructive testing
  • 相关文献

参考文献3

二级参考文献34

  • 1张广纯.电磁声(EMA)检测技术的研究、开发与工程化[J].应用声学,1995,14(2):1-6. 被引量:13
  • 2MIRKHANI K,CHAGGARES C,MASTERSON C,et al.Optimal design of EMAT transmitters[J].NDT & E International,2004,37(3):181-193.
  • 3JIAN X,DIXON S,EDWARDS R,et al.Effect on ultrasonic generation of a backplate in electromagnetic acoustic transducer[J].Journal of Applied Physics,2007,102:0249091-0249096.
  • 4HIRAO M,OGI H.EMATS for science and industry:Non-contacting ultrasonic measurements[M].Boston:Kluwer Academic Publishers,2003.
  • 5HIRAO M,OGI H,YASUI H.Contactless measurement of bolt axial stress using a shear-wave electromagnetic acoustic transducer[J].NDT & E International,2001,34(3):179-183.
  • 6KALTENBACHER Computer optimization of electromagnetic acoustic transducers[J].Ultrasonics Symposium,1998,1(2):1029-1034.
  • 7MAXFIELD B W,LINZER M.Design of permanent magnet electromagnetic acoustic-wave transducers (EMATS)[J].Ultrasonics Symposium Proceedings,IEEE Cat.,1976:22-25.
  • 8HUANG Songling,ZHAO Wei,ZHANG Yongsheng,et al.Study on the lift-off effect of EMAT[J].Sensors and Actuators A:Physical,2009,153(2):218-221.
  • 9DUTTON B,BOONSANG S,DEWHURST R J.Modelling of magnetic fields to enhance the performance of an in-plane EMAT for laser-generated ultrasound[J].Ultrasonics,2006,44(1):657-665.
  • 10MACLAUCHLAN D,CLARK S,COX B.Recent advancements in the application of EMATs to NDE[C/CD]// The 16th World Conference on NDT,Aug.30-Sep.3,2004,Montreal,Canada,2004.

共引文献48

同被引文献71

引证文献13

二级引证文献61

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;