期刊文献+

Use of 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide and graphene oxide for separation and preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ) ions in different samples 被引量:2

Use of 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide and graphene oxide for separation and preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ) ions in different samples
原文传递
导出
摘要 A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions. A simple and selective method using a column packed with graphene oxide(GO) as a solid phase extractant has been developed for the multi-element preconcentration of Fe(Ⅲ),Ni(Ⅱ),Cu(Ⅱ) and Zn(Ⅱ)ions prior to flame atomic absorption spectrometric determinations.The method is based on the sorption of mentioned ions on synthesized GO using 2-(tert-butoxy)-N-(3-carbamothioylphenyl)acetamide as a chelating agent.Several parameters on the extraction and complex formation were optimized.Under the optimized conditions(pH 6,flow rate 9 mL/min),metal ions were retained on the column,then quantitatively eluted by HNO3solution(5 mL,3.0 mol/L).The preconcentration factor was calculated as250.The detection limits for the analyte ions of interest were found in the range of 0.11 ng/mL(Ni2+) to0.63 ng/mL(Cu2+).The column packed with GO was adequate for metal ions separation in matrixes containing alkali,alkaline earth,transition and heavy metal ions.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第5期791-793,共3页 中国化学快报(英文版)
关键词 Solid phase extraction Transition metals Graphene oxide Flame atomic absorption spectrometry Solid phase extraction Transition metals Graphene oxide Flame atomic absorption spectrometry
  • 相关文献

参考文献6

二级参考文献53

  • 1Zhang, Shao Wen,Zou, Cun Jie,Luo, Nan,Weng, Qian Feng,Cai, Ling Shuang,Wu, Cai Ying,Xing, Jun.Determination of urinary 8-hydroxy-2′-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction[J].Chinese Chemical Letters,2010,21(1):85-88. 被引量:6
  • 2H.E. Nice, M.C. Thomdyke, D. Morritt, et al. Mar. Pollut. Bull. 40 (2000) 491.
  • 3G. Flouriot, E Pakdel, B. Ducouret, et al. J. Mol. Endocrinol. 15 (1995) 143.
  • 4A.M. Soto, T.M. Lin, H. Justicia, et al. Adv. MOd. Environ. Toxicol. (1992) 295.
  • 5J. Lopez-Darias, V. Pino, J.H. Ayala, et al. Anal. Bioanal. Chem. 391 (2008) 735.
  • 6C. Stavrakakis, R. Colin, V. Hequet, et al. Environ. Technol. 29 (2008) 279.
  • 7Y.X. She, J. Wang, Y.Q. Zheng, et al. Food Chem. 132 (2012) 502.
  • 8G.A. Evtugyn, S.A. Eremin, R.P. Shaljamova, et al. Biosens. Bioelectron. 22 (2006) 56.
  • 9L. Nunez, E. Turiel, J.L. Tadeo, J. Chromatogr. A 1146 (2007) 157.
  • 10M. Rezaee, Y. Yamini, S. Shariati, et al. J. Chromatogr. A 1216 (2009) 1511.

共引文献18

同被引文献21

引证文献2

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部