期刊文献+

Impact of Wind Power on the ATC Values in Hydro-Dominated Power System

Impact of Wind Power on the ATC Values in Hydro-Dominated Power System
下载PDF
导出
摘要 The wind power generation is increasing in many countries as a result of decreasing technology costs, active government policies for renewable energy sources, environmental concerns, etc.. This paper investigates the impact of wind power generation on ATC (available transmission capacity) calculation. In order to determine the maximum incremental MW transfer possible between two parts of a power system without violating any specified limits, ATCs are calculated. When calculating ATC values, it is necessary to assume production and consumption pattern in power system. Production of wind power depends on the wind speed, which is a random variable and it is impossible to forecast exactly the production of wind power that is needed for the ATCs calculation. In order to investigate influence of the stochastic wind power production on the ATCs value, computer model of Croatian electric power system is made in Power World Simulator. ATCs are calculated for southern part of Croatian power system in which besides wind power, hydro power plants are only type of power generation. Available wind speed measurements are used as input data for wind power production. The results of the ATC calculation for different scenario of wind power production and location in the Southern Croatian power system are presented and discussed in the paper.
出处 《Journal of Energy and Power Engineering》 2014年第7期1293-1300,共8页 能源与动力工程(美国大卫英文)
关键词 Available transmission capacity wind power hydro power computer model transmission system. 风力发电 电力系统 计算机模型 ATC值 风电生产 水电 电对 克罗地亚
  • 相关文献

参考文献20

  • 1Christie, R. D., Wollenberg, B. F., and Wangensteen, I. 2000. "Transmission Management in the Deregulated Environment." Proceedings of the IEEE 88 (2): 170-95.
  • 2European Network of Transmission System Operators. 2001. Definitions of Transfer Capacities in Liberalized Electricity Markets.Final report.
  • 3Chowdhury, A. A. 2005. "Reliability Models for Large Wind Farms in Generation System Planning." In IEEE Power Engineering Society General Meeting, 1926-33.
  • 4Official Power World web site. Accessed January 20, 2014. www.powerworld.com.
  • 5Luna, L., Martinez, J., Pacual, V., and Valino, V. 2011. "Impact of wind power generation on the ATC value." Presented at 17th Power Systems Computation Conference, Stockholm, Sweden.
  • 6Van Ness, J. E., Griffin, J.H. 1961. "Elimination Method for Load Flow Studies." AIEE Trans. on Power Apparatus and Systems 80: 299-302.
  • 7Saner, P. W. 1981. "On the Formulation of Power Distribution Factors for Linear Load Flow Methods." IEEE Transaction on Power Apparatus and Systems 100 (2): 764-70.
  • 8Knezevic, G., Fekete, K., and Nikolovski, S. 2009. "Visualization of Voltage Profile and Power Flow in Croatian Power System." In 32nd International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO), 381-85.
  • 9Fekete, K., Knezevic, G., Nikolovski, S., Slipac, G., Sumper, A., and Ramirez, R. 2007. "Different Cross-Border Energy Transits in Future Croatian Power System." In 7th Balkan Power Conference (BPC), 52-8.
  • 10Nikolovski, S., Topic, D., Fekete, K., and Slipac, G. 2011. "The Influence of Wind Park Krs-Padene on Reliability Indices of 110 kV Transmission Network." In 8th International Conference on the European Energy Market (EEM), 870-875.