期刊文献+

Effect of fixing distal radius fracture with volar locking palmar plates while preserving pronator quadratus 被引量:14

Effect of fixing distal radius fracture with volar locking palmar plates while preserving pronator quadratus
原文传递
导出
摘要 Background L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons.But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ.Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus.The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.Methods Between September 2010 and April 2012,65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies).The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications.All surgeries were completed by the same trained team.The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females.We compared the two groups for wrist pain,forearm range of motion,grip strength,pedoperative complications and wrist functional recovery score.Results The minimum follow-up for the whole cohort was one year.The differences between the two groups were significant with regard to wrist pain,forearm range of motion,grip strength and wrist function at 1,2,and 6 weeks postoperatively,but insignificant at 6 and 12 months postoperatively.No significant differences were found in the pedoperative complications and radiographs postoperatively.Conclusions Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates,as this technique can yield better early wrist function and shorten the rehabilitation. Background L-shaped incision of pronator quadratus (PQ) muscle along its radial and distal borders was always taken for distal radius fractures reduction and internal fixation.Repair of the PQ muscle was always recommended at the end of operation for some instructive reasons.But repair of PQ is not satisfied because of poor quality of muscle and fascial tissues which may cause pain or impede forearm pronation and supination for post-operative scarring around PQ.Inserting the locking palmar plate to pass under the pronator quadratus muscle and the locking screws are inserted through miniincisions in pronator quadratus in some patients with distal radius fractures is a reasonable technique which can preserve the pronator quadratus.The purpose of this study was to evaluate and compare the clinical effects after volar plating of the distal radius fractures while preserving the pronator quadratus and pronator quadratus repair.Methods Between September 2010 and April 2012,65 patients (42 males and 23 females; aged 20-68 years and a mean age of 42.5 years) with distal radius fracture underwent open reduction and internal fixation using the volar locking palmar plates (Depuy or Smith companies).The patients were classified as 23A-2 through 23C-3 according to the Orthopaedic Trauma Association (OTA) classifications.All surgeries were completed by the same trained team.The volar locking palmar plates of distal radius performed with preserving pronator quadratus group involved 30 patients including 19 males and 11 females and performed with pronator quadratus repair group involved 35 patients including 23 males and 12 females.We compared the two groups for wrist pain,forearm range of motion,grip strength,pedoperative complications and wrist functional recovery score.Results The minimum follow-up for the whole cohort was one year.The differences between the two groups were significant with regard to wrist pain,forearm range of motion,grip strength and wrist function at 1,2,and 6 weeks postoperatively,but insignificant at 6 and 12 months postoperatively.No significant differences were found in the pedoperative complications and radiographs postoperatively.Conclusions Preservation of the pronator quadratus muscle is a satisfactory method for the treatment of majority of the fractures of the distal radius with volar locking palmar plates,as this technique can yield better early wrist function and shorten the rehabilitation.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2014年第16期2929-2933,共5页 中华医学杂志(英文版)
关键词 distal radius fracture open reduction palmar plate pronator quadratus distal radius fracture open reduction palmar plate pronator quadratus
  • 相关文献

参考文献1

二级参考文献12

  • 1Jiang BG,Long KY,Zhang DY,Fu ZG,Chen JH.Strategies of treatment of distal radius fractures.Chin J Orthop Trauma (Chin) 2004; 6:1118-1121.
  • 2Gruber G,Gruber K,GiessaufC,Clar H,Zacherl M,Fuerst F,et al.Volar plate fixation of AO type C2 and C3 distal radius fractures,a single-center study of 55 patients.J Orthop Trauma 2008; 22:467-472.
  • 3Egol KA,Walsh M,Romo-Cardoso S,Dorsky S,Paksima N.Distal radial fractures in the elderly:operative compared with nonoperative treatment.J Bone Joint Surg Am 2010; 92:1851-1857.
  • 4Orbay JL,Touhami A.Current concepts in volar fixed-angle fixation of unstable distal radius fractures.Clin Orthop Relat Res 2006; 445:58-67.
  • 5Gwathmey FW Jr,Brunton LM,Pensy RA,Chhabra AB.Volar plate osteosynthesis of distal radius fractures with concurrent prophylactic carpal tunnel release using a hybrid flexor carpi radialis approach.J Hand Surg Am 2010; 35:1082-1088.
  • 6Protopsaltis TS,Ruch DS.Volar approach to distal radius fractures.J Hand Surg Am 2008; 33:958-965.
  • 7Kamei S,Osada D,Tamai K,Kato N,Takai M,Kameda M,et al.Stability of volar locking plate systems for AO type C3 fractures of the distal radius:biomechanical study in a cadaveric model.J Orthop Sci 2010; 15:357-364.
  • 8Zebaze RM,Ghasem-Zadeh A,Bohte A,Iuliano-Bums S,Mirams M,Price RI,et al.Intracortical remodelling and porosity in the distal radius and post-mortem femurs of women:a cross-sectional study.Lancet 2010,15; 375:1729-1736.
  • 9Gruber G,Zacherl M,Giessauf C,Glehr M,Fuerst F,Liebmann W,et al.Quality of life after volar plate fixation of articular fractures of the distal part of the radius.J Bone Joint Surg Am 2010; 92:1170-1178.
  • 10Huang JJ.Different approaches of dorsal or metacarpal plate fixation for unstable distal radius fractures.Chin J Reparat Reconstr Surg (Chin) 2008,22:948-951.

共引文献7

同被引文献60

引证文献14

二级引证文献180

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部