期刊文献+

Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan 被引量:2

Monitoring actual performance of ground source heat pump system using GPRS-based data transmission: A case analysis in Tangshan
下载PDF
导出
摘要 The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability. The energy efficiency monitoring is an essential precondition for ground source heat pump system's controlling and energy saving operation. Based on the data monitoring applied in the school building, this work is focused on the parameters acquisition and operation analysis of the GSHP system in Tangshan. Results show the average COPs(coefficient of performance) are2.85 and 2.70 in summer and winter, respectively, and heat(cold) unbalance underground existed after whole year operation. The analysis of data also indicates that the direct borehole air-conditioning saved some power consumption obviously in the early stage of summer and energy saving of the GSHP system depended remarkably on its operation and management level. Besides the observation points of ground temperature are laid for a large-scale GSHP system, and the hydraulic balance of the pipes group needs to be concerned specially in safeguarding better reliability.
出处 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1554-1562,共9页 中南大学学报(英文版)
基金 Project(2012BAJ06B04)supported by"12th Five-Year Plan"National science and Technology,China Project(2014-228)supported by Department of Housing and Urban Rural Development of Hebei,China
关键词 ground source heat pump monitoring operation performance 地源热泵系统 数据监测 案例分析 数据传输 GPRS 使用性能 唐山 节能运行
  • 相关文献

参考文献2

二级参考文献7

共引文献58

同被引文献10

引证文献2

二级引证文献2