Design Consideration for High Power Density GaN Buck-Rectifier in ISOP-IPOS Converter based dc Distribution, System

Design Consideration for High Power Density GaN Buck-Rectifier in ISOP-IPOS Converter based dc Distribution, System
下载PDF
导出
摘要 GaN (gallium nitride) buck-rectifier has been proposed to realize high power density ISOP (input series and output parallel)-IPOS (input parallel and output series) converter-based dc distribution system. The ultra-low loss bi-directional switch can be developed by the GaN power device because of the low on-resistance, the high-speed switching behavior and its own device structure. The buck-rectifier using the GaN bi-directional switches has the potential to achieve higher power density than the commonly utilized boost-rectifier. Availability of the GaN-HEMT (high electron mobility transistor) for the buck rectifier has been verified taking the theoretical limit of the on-resistance and the switching loss energy into account. Design consideration for a high power density buck-rectifier has been also conducted and the application effect of the GaN bidirectional switches has been evaluated quantitatively. The ISOP-IPOS converter-based dc (direct current) distribution system takes full advantage of the buck-rectifier and the rectifier using GaN devices contributes to realizing higher power density dc distribution system.
出处 《Journal of Energy and Power Engineering》 2015年第6期574-584,共11页 能源与动力工程(美国大卫英文)
关键词 ac (alternate current)-dc converter GaN (gallium nitride) power device power density dc distribution ISOP-IPOStopology. 直流配电系统 高功率密度 整流器 氮化镓 转换器 降压 设计 高电子迁移率晶体管
  • 相关文献

参考文献1

二级参考文献32

  • 1R.R. Schmidt, C. Belady, A. Classen, T. Davidson, M.K. Herrlin, S. Novotny, et al., Evolution of Data Center Environmental Guidelines, ASHRAE Transactions, Partl, 2004, Vol. 110, pp. 559-566.
  • 2Y. Sugiyama, Green ICT toward low carbon society-green R & D activities in NTT, in: Proceedings of 4th International Workshop on Green Communications, Kyoto, Japan, 2011.
  • 3J.S. Glaser, A.F. Witulski, Output plane analysis of load-sharing in multiple-module converters systems, IEEE Trans. on Power Electronics 9 (1) (1994) 43-50.
  • 4R. Ayyanar, R. Giri, N. Mohan, Active input-voltage and load-current sharing in input-series and output-parallel connected modular DC-DC converters using dynamic input-voltage reference scheme, IEEE Trans. on Power Electronics 19 (6) (2004) 1462-1473.
  • 5L. Wang, X. He, Input-series and output-parallel connection modular DC-DC converters with interleaved constant duty cycle control strategy, in: Proceedings of the33rd Annual Conference of the IEEE Industrial Electronics Society (IECON), Taipei, Taiwan, 2007, pp. 1901-1906.
  • 6J.W. Kimball, J.T. Mossoba, P.T. Krein, A stabilizing, high-performance controller for input series-output parallel converters, IEEE Trans. on Power Electronics 23 (3) (2008) 1416-1427.
  • 7C. Martinez, T. Jalakas, D. Vinnikov, A. Lazaro, A. Barrado, QZSI DC/DC converters in input-series output-parallel connection for distributed generation, in: Proceedings of International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), Sorrento, Italia, 2012, pp. 952-957.
  • 8J.W. Kim, J.S. You, B.H. Cho, Modeling, control, and design of input-series-output-parallel-connected converter for high-speed-train power system, IEEE Trans. on Industrial Electronics 48 (3) (2001) 536-544.
  • 9J.P. Lee, B.D. Min, T.J. Kim, D.W. Yoo, J.Y. Yoo, High efficient interleaved input-series-output-parallel-connected DC/DC converter for photovoltaic power conditioning system, in: Proceedings of Energy Conversion Congress and Exposition (ECCE), California, U.S., 2009, pp. 327-329.
  • 10J.S. Glaser, J. Nasadoski, R. Heinrich, A 900 W, 300 V to 50 V DC-DC power converter with a 30 MHz switching frequency, in: Proceedings of 24th Applied Power Electronics Conference and Exposition (APEC), Washington DC, U.S., 2009, pp. 1121-1128.