Summary: Lead placement for ventricular pacing variably impacts the physiological benefit of the pa- tient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63-4-21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the sep- tum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projec- tion. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No dif- ferences were identified in threshold, impedance or R-wave sensing between the two groups at 1 st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
Summary: Lead placement for ventricular pacing variably impacts the physiological benefit of the pa- tient. This study evaluated the ventricular lead performance and safety of right ventricular outflow tract septal pacing in patients with bradyarrhythmia in South China over 60-month follow-up. Totally, 192 patients (108 males, and 84 females, 63-4-21 years old) with bradyarrhythmia were randomly divided into two groups. The right ventricular outflow tract septum (RVOTs) group had lead placement near the sep- tum (n=97), while the right ventricular apex (RVA) group had a traditional apical placement (n=95). RV septal lead positioning was achieved with a specialized stylet and confirmed using fluoroscopic projec- tion. All patients were followed up for 60 months. Follow-up assessment included stimulation threshold, R-wave sensing, lead impedance and lead complications. The time of electrode implantation in both the ROVTs and RVA groups were significantly different (4.29±0.61 vs. 2.16±0.22 min; P=0.009). No dif- ferences were identified in threshold, impedance or R-wave sensing between the two groups at 1 st, 12th, 36th and 60th month during the follow-up period. No occurrence of electrode displacement, increased pacing threshold or inadequate sensing was found. The long-term active fixation ventricular electrode performance in RVOTs group was similar to that in RVA group. RVOTs pacing near the septum using active fixation electrodes may provide stability during long-term follow-up period.
基金
supported in part by grants from the Science and Technology Key Foundation of Guangdong Province(No.2010B031600166)
the Science and Technology Foundation of Guangdong Province(No.2011B061300072)