A nanocomposite consisting of silica-coated magnetite and phenyl-functionalized graphene oxide for extraction of polycyclic aromatic hydrocarbon from aqueous matrices 被引量:2

A nanocomposite consisting of silica-coated magnetite and phenyl-functionalized graphene oxide for extraction of polycyclic aromatic hydrocarbon from aqueous matrices
原文传递
导出
摘要 In this study,graphene oxide was covalently immobilized on silica-coated magnetite and then modified with 2-phenylethylamine to give a nanocomposite of type Fe3O4@SiO2@GO-PEA that can be applied to the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons(PAHs) from water samples.The resulting microspheres(Fe3O4@SiO2@GO-PEA) were characterized by Fourier transform-infrared spectroscopy(FT-IR),scanning electron microscopy(SEM),CHNS elemental analysis,and vibrating sample magnetometry(VSM) techniques.The adsorbent possesses the magnetic properties of Fe3O4 nanoparticles that allow them easily to be separated by an external magnetic field.They also have the high specific surface area of graphene oxide which improves adsorption capacity.Desorption conditions,extraction time,amount of adsorbent,salt concentration,and pH were investigated and optimized.Following desorption,the PAHs were quantified by gas chromatography with flame ionization detection(GC-FID).The limits of detection(at an S/N ratio of 3) were achieved from 0.005 to0.1 μg/L with regression coefficients(R2) higher than 0.9954.The relative standard deviations(RSDs) were below 5.8%(intraday) and 6.2%(inter-day),respectively.The method was successfully applied to the analysis of PAHs in environmental water samples where it showed recoveries in the range between 71.7%and 106.7%(with RSDs of 1.6%to 8.4%,for n = 3).The results indicated that the Fe3O4@SiO2@GO-PEA microspheres had a great promise to extraction of PAHs from different water samples. In this study,graphene oxide was covalently immobilized on silica-coated magnetite and then modified with 2-phenylethylamine to give a nanocomposite of type Fe3O4@SiO2@GO-PEA that can be applied to the magnetic solid-phase extraction of polycyclic aromatic hydrocarbons(PAHs) from water samples.The resulting microspheres(Fe3O4@SiO2@GO-PEA) were characterized by Fourier transform-infrared spectroscopy(FT-IR),scanning electron microscopy(SEM),CHNS elemental analysis,and vibrating sample magnetometry(VSM) techniques.The adsorbent possesses the magnetic properties of Fe3O4 nanoparticles that allow them easily to be separated by an external magnetic field.They also have the high specific surface area of graphene oxide which improves adsorption capacity.Desorption conditions,extraction time,amount of adsorbent,salt concentration,and pH were investigated and optimized.Following desorption,the PAHs were quantified by gas chromatography with flame ionization detection(GC-FID).The limits of detection(at an S/N ratio of 3) were achieved from 0.005 to0.1 μg/L with regression coefficients(R2) higher than 0.9954.The relative standard deviations(RSDs) were below 5.8%(intraday) and 6.2%(inter-day),respectively.The method was successfully applied to the analysis of PAHs in environmental water samples where it showed recoveries in the range between 71.7%and 106.7%(with RSDs of 1.6%to 8.4%,for n = 3).The results indicated that the Fe3O4@SiO2@GO-PEA microspheres had a great promise to extraction of PAHs from different water samples.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第5期164-173,共10页 环境科学学报(英文版)
关键词 Graphene oxide Polycyclic aromatic hydrocarbons Magnetic separation Nanoadsorbent Gas chromatography Water samples analysis Graphene oxide Polycyclic aromatic hydrocarbons Magnetic separation Nanoadsorbent Gas chromatography Water samples analysis
  • 相关文献

参考文献1

二级参考文献40

  • 1ATSDR (Agency for Toxic Substances and Disease Registry),1995.Toxicological Profile for Polycyclic Aromatic Hydrocarbons.US Department of Health and Human Services Atlanta.
  • 2Brum D M,Cassella R J,Pereira Netto D A,2008.Multivariate optimization of a liquid-liquid extraction of the EPA-PAHs from natural contaminated waters prior to determination by liquid chromatography with fluorescence detection.Talanta,74:1392-1399.
  • 3Cai Y,Jiang G,Liu J,Zhou Q,2003a.Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of bisphenol A,4-n-nonylphenol,and 4-tert-octylphenol.Analytical Chemistry,75:2517-2521.
  • 4Cai Y,Jiang G,Liu J,Zhou Q,2003b.Multi-walled carbon nanotubes packed cartridge for the solid-phase extraction of several phthalate esters from water samples and their determination by high performance liquid chromatography.Analytica Chimica Acta,494:149-156.
  • 5Cai Y,Mou S,Lu Y,2005.Multi-walled carbon nanotubes as a solid-phase extraction adsorbent for the determination of chlorophenols in environmental water samples.Journal of Chromatography A,1081:245-247.
  • 6Camel V,2003.Solid phase extraction of trace elements.Spectrochim Acta Part B,58:1177-1233.
  • 7Chen C T,Chen Y C,2005.Fe3O4/TiO2 core/shell nanoparticles as affinity probes for the analysis of phosphopeptides using rio2 surface-assisted laser desorption/ionization mass spectrometry.Analytical Chemistry,77:5912-5919.
  • 8Decision No 2455/2001/EC of the European Parliament and of the Council of 20 November 2001 establishing the list of priority substances in the field of water policy and amending Directive 2000/60/EC,(15 December) 2001.Official Journal of the European Communities,L331:1-5.
  • 9Directive 2000/60/EC of the European Parliament and of the Council establishing a framework for Community action in the field of water policy.CELEX-EUR official Journal L327,22 December 2000.1-72.
  • 10Diebold U,2003.The surface science of titanium dioxide.Surface Science Reports,48:53-229.