期刊文献+

Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography:Ⅱ.Influence of Several Testing Conditions 被引量:2

Determination of Organic Acids in Root Exudates by High Performance Liquid Chromatography:Ⅱ.Influence of Several Testing Conditions
下载PDF
导出
摘要 Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH. Effects of column temperature and flow rate on separation of organic acids were studied by determining nine low-molecular-weight organic acids on reversed- phase C18 column, using high performance liquid chromatography (HPLC) with a wavelength of UV (ultraviolet) 214 urn and a mobile phase of 18 mmol L-1 KH2PO4 buffer solution (pH 2.1). The thermal stability of organic acids was determined by comparing the recoveries of organic acids in different temperature treatments. The relationships between column temperature, flow rate or solvent pH and retention time were analyzed. At low solvent pH, separation efficiency of organic acids was increased by raising the flow rate of the solvent because of lowering the retention time of organic acids. High column temperature was unfavorable for the separation of organic acids. The separating effect can be enhanced through reducing column temperature in organic acid determination due to increasing retention time. High thermal stability of organic acids with low concentrations was observed at temperature of 40 ℃-45℃. Sensitivity and separation effect of organic acid determination by HPLC were clearly improved by a combination of raising flow rate and lowering column temperature at low solvent pH.
出处 《Pedosphere》 SCIE CAS CSCD 1999年第1期45-52,共8页 土壤圈(英文版)
关键词 chromatographic conditions high performance liquid chromatography (HPLC) organic acids root exudates HPLC法 根渗出物 有机酸 测定条件
  • 相关文献

参考文献1

  • 1申建波,Pedosphere,1998年,8卷,2期,97页

同被引文献19

引证文献2

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部