摘要
为了研究主管局部加内套管的加强K型搭接节点的滞回性能,采用有限元分析软件ANSYS设计了K型搭接节点有限元分析模型,对节点2个支管同时施加轴向负相关低周往复荷载,得到节点的破坏模式、滞回曲线和骨架曲线,分析节点的承载性能和耗能性能,进而评价节点的抗震性能。结果表明:未加强K型节点主要以主管塑性破坏为主,而加强节点主要开始于支管屈曲破坏;主管局部加内套管的加强方式使得节点承载力可提高30%左右,但对搭接节点的耗能影响不大。
In order to study on the hysteretic performance of reinforced K-type overlapping node in the main pipe and inner sleeve,the author will make use of software of finite element analysis ANSYS and design K-type overlapping node finite element analysis model to exert the axial negatively correlated low-cycle load on two branch pipes,as a result,get the failure mode,hysteretic curve and skeleton curve of node,then,analyze the load-carrying performance and energy performance of node,finally,evaluate its anti-seismic property.The results show that the unreinforced K-type node is based on the plastic failure of main pipe,but,the reinforced node begins with the buckling destruction of branch pipe;Although the reinforcement mode(namely,main pipe and inner sleeve)can enhance the node bearing force for 30%,it has less impact on the energy dissipation of overlapping node.
作者
高栋
杨文伟
索雅琪
林健康
Gao Dong;Yang Wenwei;Suo Yaqi;Lin Jiankang(College of Civil and Hydraulic Engineering,Ningxia University,Yinchuan 750021,China)
出处
《甘肃科学学报》
2018年第2期79-83,共5页
Journal of Gansu Sciences
基金
国家自然科学基金资助项目(51468054)
关键词
加强节点
K型搭接节点
滞回性能
有限元分析
Reinforced node
K-type overlapping node
Hysteretic performance
FEM study