摘要 传统稳态平板法测定绝热材料导热系数实验台稳定时间长、精度低,难以满足教学要求。针对原实验台存在的问题,对其热保护电气控制系统、水冷系统、热功率测量系统、温度测量系统、机械系统和测控电路系统进行了优化设计。实验结果表明,优化设计后的实验台导热系数测量精度提高了5. 5%,稳定时间缩短了50%以上。该实验台起到了提高实验教学质量,改善实验教学条件的作用,为传统实验台的优化设计提供了新思路。 The thermal conductivity measuring under steady-state based on the guarded hot plate method is a very important experiment in heat transfer course.Traditional instrument is used to measure thermal conductivity,needed relatively long time to maintain a steady-state,and had a low precision.Hence it could not match the teaching requirements.In order to solve the aforementioned problems,optimal design was conducted on electrical control system of the guarded hot plate,water cooling system,thermal power measurement system,temperature measurement system,mechanical system and measurement and control circuit system.Experimental results showed that the accuracy of temperature measurement was improved by 5.5%,the time to maintain a steady-state was shortened over 50%.It has improved conditions and quality of experimental teaching,and has provided a new approach for optimal design of traditional experiment instruments.
作者 赵晓文 矫振伟 黄海珍 邱俊达 高雪 ZHAO Xiaowen;JIAO Zhenwei;HUANG Haizhen;QIU Junda;QIU Jun(State Key Laboratory of Automotive Simulation and Control,Changchun 130025,China;Department of Thermal Engineering, Jilin University,Changchun 130025,China;Jilin Hongyuan Construction Co.,Ltd.,Changchun 130028,China)
出处 《实验室研究与探索》 CAS 北大核心 2018年第9期66-70,共5页 Research and Exploration In Laboratory
基金 吉林省科技厅青年人才基金项目(20180520066JH) 吉林大学实验技术项目(409020720108) 吉林大学大学生创新训练项目(2017A42121)
关键词 稳态平板法 绝热材料 导热系数 优化设计 guarded hot plate method thermal insulation material thermal conductivity optimal design
  • 相关文献

参考文献7

二级参考文献42

共引文献125

同被引文献73

引证文献9

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部