摘要
采用混凝—臭氧催化氧化—曝气生物滤池—臭氧催化氧化组合工艺对垃圾焚烧发电厂渗滤液超滤出水进行深度处理。结果表明,该组合工艺对渗滤液超滤出水中的COD和氨氮均有良好的去除效果,整体去除率分别达到89%和78%,最终出水中的COD和氨氮平均浓度满足《生活垃圾填埋场控制标准》(GB 16889—2008)表3中的排放限值标准。该组合工艺的综合处理成本约为8.07元/t,具有较好的经济性。
The combined process,coagulation flocculation-catalytic ozonation-biological aerated filter(BAF)-cata- lytic ozonation,has been used for the advanced treatment of the leachate ultrafiltration(UF) effluent from a waste in- cineration power plant. The results show that the combined process has excellent removing effect on both COD and NH4+-N of the leachate UF effluent. The total removing rates of them are 89% and 78%,respectively. The average con- centrations of COD and NH4+-N in the final effluent can reach the limit value specified in Table 3 of Control Standard of Domestic Waste Landfill(GB 16889-2008). The total treatment cost of the combined process is about RMB 8.07 yuan/t,having comparatively good economic effect.
作者
郭智
刘杰
邱明建
徐伟
李海涛
Guo Zhi;Liu Jie;Qiu Mingjian;Xu Wei;Li Haitao(CECEP Engineering Technology Research Institute Co.,Ltd.,Beijing 100082,China)
出处
《工业水处理》
CAS
CSCD
北大核心
2019年第5期29-33,共5页
Industrial Water Treatment
基金
中国节能环保集团有限公司科技创新项目(cecep-kj-2015-001)
关键词
垃圾渗滤液尾水
混凝
臭氧催化氧化
曝气生物滤池
leachate tail water
coagulation flocculation
catalytic ozonation
biological aerated filter