摘要
针对LF炉水冷炉盖漏水事故的原因,对水冷炉盖内部结构、进水回水管路方式进行改造,使得水冷炉盖的在线使用寿命提高一倍以上。
Based on the causes of water leakage at the LF water cooling furnace cover, the internal structure of the water-cooling furnace cover and the way of inlet and outlet water pipeline are modified. It makes the online service lifetime of the water cooling furnace cover increase by more than one time.
作者
董水秀
史页殊
贾东升
尚德良
DONG Shui-xiu;SHI Ye-shu;JIA Dong-sheng;SHANG De-liang(Steel Making Department of Bayuquan Steel Company of Angang Steel Co., Ltd., Yingkou)
出处
《冶金设备管理与维修》
2019年第4期50-52,共3页
Metallurgical Equipment Management and Maintenance
关键词
LF精炼炉
水冷炉盖
漏水
设备改造
LF
refining furnace
water cooling furnace cover
water leakage
equipment modification