国内某新建造纸企业配套废水处理站设计规模60000 m^3/d,废水处理采用预处理+好氧生物处理+混凝沉淀+Fenton氧化处理工艺,出水CODCr≤50 mg/L,SS≤13 mg/L,直接进入后续中水回用单元;中水回用单元采用预处理+超滤反渗透工艺进行处理,反渗透出水CODCr≤10 mg/L,TDS≤180 mg/L,系统中水回收率70%,脱盐率97%。回用水送至厂区原水池,为企业新增用水源1512万m^3/a,约占企业总用水量的50%,极大地缓解了企业用水压力。
The scale of wastewater treatment station in the paper mill was 60000 m^3/d.The wastewater treatment adopted the process of pre⁃treatment+aerobic biological treatment+coagulation sedimentation+Fenton oxidation,and the effluent(CODCr≤50 mg/L and SS≤13 mg/L)was subsequently treated by the process of pretreatment+ultrafiltration reverse osmosis process in order to implement recycling.The CODCr of produced water from reverse osmosis was less than 10 mg/L and TDS was less than 180 mg/L.The system recovery rate was 70%and the desalination rate was 97%.The recycled water was sent to the original water pool of the plant,which provided 15.12 million m^3 of water per year to the enterprise,accounting for about 50%of the total water consumption of the enterprise,greatly alleviating the pressure of the enter⁃prise's water supply.
作者
丁绍峰
张萌
付大勇
苏威
DING Shaofeng;ZHANG Meng;FU Dayong;SU Wei(Beijing Guodian Futong Science and Technology Development Co.,Ltd.,Beijing,100070;Nanri Group Corporation/State Grid Electric Power Research Institute,Nanjing,Jiangsu Province,210003)
出处
《中国造纸》
CAS
北大核心
2019年第12期78-83,共6页
China Pulp & Paper
关键词
制浆造纸
废水处理
中水回用
pulping and paper
wastewater treatment
reuse of reclaimed water