期刊文献+

木钉斜接对SPF连接性能的影响

EFFECT OF INCLINED WOOD NAIL ON CONNECTION PERFORMANCE OF SPF
下载PDF
导出
摘要 研究木钉以不同的角度连接S P F规格材时对木结构节点抗剪性能的影响。将木钉以30°,45°,60°,75°,90°等多角度钉入SPF试件,分析试件受到剪拉、剪压力时节点承载力的变化规律,试验结果证明,试件受剪拉力时,钉入角度为60°为最佳角度,其节点承载力、刚度和延性系数最大。 The influence of wooden nails connected with SPF specification lumber at different angles on the shear resistance of wood structure joints is studied.Nail the dowel into the SPF specimen at 30°,45°,60°,75°,90°and other angles,and analyze the change law of the joint bearing capacity when the specimen is subjected to shear tension and shear pressure.The test results prove that the specimen When under shear tension,the nail-in angle of 60°is the best angle,and its joint bearing capacity,stiffness and ductility coefficient are the largest.
作者 王菲彬 王永兵 朵玉贤 周斌 阙泽利 WANG Fei-bin;WANG Yong-bing;DUO Yu-xian;ZHOU Bin;QUE Ze-li(College of Landscape Architecture,Nanjing Forestry University,210037,Nanjing,China;Suzhou Zeerqi Wood Structure Technology Co.,Ltd.,215000,Suzhou,Jiangsu,China;College of Materials Science and Engineering,Nanjing Forestry University,210037,Nanjing,China)
出处 《建筑技术》 2021年第3期294-296,共3页 Architecture Technology
基金 国家自然科学基金(31670566)。
关键词 木结构 钉连接 木钉 承载性能 timber structure nailed joint wood nail load-carrying performance
  • 相关文献

参考文献3

二级参考文献30

  • 1俞茂宏,ODA Y,方东平,赵均海,张德良,竺润祥,车爱兰.中国古建筑结构力学研究进展[J].力学进展,2006,36(1):43-64. 被引量:49
  • 2Canadian Wood Council. Wood design manual[M]. 1990: 213- 303.
  • 3Samuel L Z, Douglas R R. Review of test methods used to determine the corrosion rate of metals in contact with treated wood[J].FPL-GTR-156. U S Department of Agriculture, Forest Products Laboratory,2005.
  • 4Andrew J B. Corrosion of nails in CCA-and ACA-treated wood in two environments[J]. Forest Products Journal, 1992,42 (9) ;39-41.
  • 5Ted Mooney. Electroplated coatings[M]. ASM handbook volume 13A corrosion.. Fundamentals, Testing, and Protection. 2003
  • 6Washington State University, American Forest and paper Association. Proceeding of the 9th world conference on timber engineering[C]. USA: 2006.
  • 7Robert H W, Steven M C, Deepak K S. Fire endurance model for a metal-plate-connected wood truss[R]. FPL-RP-522. U S Department of Agriculture, Forest Service, Forest Products Laboratory, 1993
  • 8Finnish Association of Civil Engineers RIL. Proceeding of the 8th world conference on timber engineering V[C]. Finland: 2004.
  • 9Bejtka I. Self-tapping screws as reinforcements in connections with dowel-type fasteners[C]. 2005, CIB-W18/38-7-4.
  • 10Lawrence A S, Robert J R, Daniel F Windorski. Fiberglass- reinforced bolted wood connections [J]. Forest Products Journal,1998, 48(9) :63-67.

共引文献31