摘要
AIM:To evaluate the differences in corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus.METHODS:In our prospective clinical trial,40 patients(60 eyes)with progressive keratoconus were randomized to undergo corneal cross-linking with transepithelial(TE group,n=30)or epithelium-off(EO group,n=30)keratoconus.Examinations comprised topography,corneal biomechanical analysis and specular microscopy at 6 mo postoperatively.RESULTS:The keratometer values were not significantly different between the TE and EO corneal cross-linked groups in different periods(each P>0.05).The corneal thickness of the EO group was greater than that of the TE group at 1 wk after the operation(each P<0.05).Regarding corneal biomechanical responses,the EO group showed a longer second applanation length than TE group(P=0.003).Regarding the corneal endothelial function,standard deviation of the endothelial cell size,and coefficient of variation in the cell area,the values of EO group were larger than those of TE group at 1 wk(P=0.011,0.026),and the percentage of hexagonal cells in EO group was lower than that in TE group at 1 and 6 mo(P=0.018,0.019).CONCLUSION:Epithelium-off corneal cross-linking may strengthen corneal biomechanics better than TE procedure can.However,the TE procedure with a lower ultraviolet-A irradiation intensity would be safer for corneal endothelial function.
基金
Supported by the National Natural Sciences Foundation of China(No.81870681)