期刊文献+

Differential diagnosis of different types of solid focal liver lesions using two-dimensional shear wave elastography 被引量:6

下载PDF
导出
摘要 BACKGROUND The clinical management and prognosis differ between benign and malignant solid focal liver lesions(FLLs),as well as among different pathological types of malignant FLLs.Accurate diagnosis of the possible types of solid FLLs is important.Our previous study confirmed the value of shear wave elastography(SWE)using maximal elasticity(Emax)as the parameter in the differential diagnosis between benign and malignant FLLs.However,the value of SWE in the differential diagnosis among different pathological types of malignant FLLs has not been proved.AIM To explore the value of two-dimensional SWE(2D-SWE)using Emax in the differential diagnosis of FLLs,especially among different pathological types of malignant FLLs.METHODS All the patients enrolled in this study were diagnosed as benign,malignant or undetermined FLLs by conventional ultrasound.Emax of FLLs and the periphery of FLLs was measured using 2D-SWE and compared between benign and malignant FLLs or among different pathological types of malignant FLLs.RESULTS The study included 32 benign FLLs in 31 patients and 100 malignant FLLs in 96 patients,including 16 cholangiocellular carcinomas(CCCs),72 hepatocellular carcinomas(HCCs)and 12 liver metastases.Thirty-five FLLs were diagnosed as undetermined by conventional ultrasound.There were significant differences between Emax of malignant(2.21±0.57 m/s)and benign(1.59±0.37 m/s)FLLs(P=0.000),and between Emax of the periphery of malignant(1.52±0.39 m/s)and benign(1.36±0.44 m/s)FLLs(P=0.040).Emax of liver metastases(2.73±0.99 m/s)was significantly higher than that of CCCs(2.14±0.34 m/s)and HCCs(2.14±0.46 m/s)(P=0.002).The sensitivity,specificity and accuracy were 71.00%,84.38%and 74.24%respectively,using Emax>1.905 m/s(AUC 0.843)to diagnose as malignant and 23 of 35(65.74%)FLLs with undetermined diagnosis by conventional ultrasound were diagnosed correctly.CONCLUSION Malignant FLLs were stiffer than benign ones and liver metastases were stiffer than primary liver carcinomas.2D-SWE with Emax was a useful complement to conventional ultrasound for the differential diagnosis of FLLs.
出处 《World Journal of Gastroenterology》 SCIE CAS 2022年第32期4715-4724,共10页 世界胃肠病学杂志(英文版)
基金 Supported by Natural Science Foundation of Shanghai of China,No.19ZR1441500,No.22ZR1458200 Science Research Foundation of Shanghai Municipal Health Commission,No.202140378 Key Program of Science and Technology Commission Foundation of Changning,Shanghai,China,No.CNKW2020Z04.
  • 相关文献

参考文献6

二级参考文献22

  • 1Ki Tae Yoon,Sun Min Lim,Jun Yong Park,Do Young Kim,Sang Hoon Ahn,Kwang-Hyub Han,Chae Yoon Chon,Mong Cho,Jun Woo Lee,Seung Up Kim.Liver Stiffness Measurement Using Acoustic Radiation Force Impulse (ARFI) Elastography and Effect of Necroinflammation[J].Digestive Diseases and Sciences.2012(6)
  • 2A. Gallotti,M. D’Onofrio,R. Pozzi Mucelli.Acoustic Radiation Force Impulse (ARFI) technique in ultrasound with Virtual Touch tissue quantification of the upper abdomen[J].La radiologia medica.2010(6)
  • 3Numminen,K,Isoniemi,H,Halavaara,J.Preoperative assessment of focal liver lesions: multidetector computed tomography challenges magnetic resonance imaging[].Acta Radiologica.2005
  • 4Bruix J,Sherman M.Management of hepatocellular carcinoma[].Hepatology.2005
  • 5Hohmann J,Albrecht T,Hoffmann CW,et al.Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents[].European Journal of Radiology.2003
  • 6Quaia E,Calliada F,Bertolotto M,et al.Characterization of focal liver lesions with contrast-specific US modes and a sulfur hexafluoride-filled microbubble contrast agent: diagnostic performance and confidence[].Radiology.2004
  • 7Vilgrain V.Advancement in HCC imaging:diagnosis, staging and treatment efficacy assessments:hepatocellular carcinoma:imaging in assessing treatment efficacy[].J Hepatobiliary Pancreat Sci.2010
  • 8Lupsorl M,Badeal R,Stefanescu H,et al.Performance of a new elastographic method (ARFI technology)compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C.Preliminary results[].J Gastrointestin Liver Dis.2009
  • 9Goertz RS,Zopf Y,Jugl V,et al.Measurement of liver elasticity with acoustic radiation force impulse (ARFI)technology:an alternative noninvasive method for staging liver fibfosis in viral hatitis[].Ultraschall in der Medizin.2010
  • 10Yu H,Wilson SR.Differentiation of Benign From MalignantLiver Masses With Acoustic Radiation Force ImpulseTechnique[].Ultrasound Quarterly.2011

共引文献43

同被引文献38

引证文献6

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部