期刊文献+

Changes in posterior corneal elevation after small incision lenticule extraction for different myopic diopters

下载PDF
导出
摘要 ●AIM:To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction(SMILE)with different myopic diopters.●METHODS:Ninety eyes of 90 patients who underwent SMILE were included in this retrospective study.Patients were allocated into three groups based on the preoperative spherical equivalent(SE):low myopia(SE≥-3.00 D),moderate myopia(-3.00 D>SE>-6.00 D)and high myopia(SE≤-6.00 D).Posterior corneal surfaces were measured by a Scheimpflug camera preoperatively and different postoperative times(1wk,1,3,6mo,and 1y).Posterior mean elevation(PME)at 25 predetermined points of 3 concentric circles(2-,4-,and 6-mm diameter)above the best fit sphere was analyzed.●RESULTS:All surgeries were completed uneventfully and no ectasia was found through the observation.The difference of myopia group was significant at the 2-mm ring at 1 and 3mo postoperatively(1mo:P=0.017;3mo:P=0.018).The effect of time onΔPME was statistically significant(2-mm ring:P=0.001;4-mm ring:P<0.001;6-mm ring:P<0.001).The effect of different corneal locations onΔPME was significant except 1wk postoperatively(1mo:P=0.000;3mo:P=0.000;6mo:P=0.001;1y:P=0.001).Posterior corneal stability was linearly correlated with SE,central corneal thickness,ablation depth,residual bed thickness,percent ablation depth and percent stromal bed thickness.●CONCLUSION:The posterior corneal surface changes dynamically after SMILE.No protrusion is observed on the posterior corneal surface in patients with different degrees of myopia within one year after surgery.SMILE has good stability,accuracy,safety and predictability.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期491-498,共8页 国际眼科杂志(英文版)
基金 Supported by Shandong Provincial Natural Science Foundation(No.ZR2022QH384).
  • 相关文献

参考文献6

二级参考文献50

  • 1杜持新,沈晔,黄智敏,忻双华.准分子激光原位角膜磨镶术后角膜后表面改变的特点及其影响因素[J].中华眼科杂志,2005,41(6):488-491. 被引量:29
  • 2周紫霞,杨亚波.飞秒激光在眼科的应用[J].国外医学(眼科学分册),2005,29(5):323-326. 被引量:7
  • 3Vestergaard A, Ivarsen AR, Asp S, et al. Small-incision lenticule extraction for moderate to high myopia: Predictability, safety, and patient satisfaction[J]. J Cataract Refract Surg, 2012, 38(1l): 2003-2010. DOI: 10.1016/j. j crs. 2012.07.021.
  • 4Shah R, Shah S, Sengupta S. Results of small incision lenticule extraction: All-in-one femtosecond laser refractive surgery[J]. J Cataract Refract Surg, 2011,37(1):127-137. DOI:10.1016/j.jcrs.2010.07.033.
  • 5Martin R, Rachidi H. Stability of posterior corneal elevation one year after myopic laser in situ keratomileusis[J], Clin Exp Optom, 2012,95(2):177-186. DOI: 10.1111/j.1444- 0938.2011.00665.x.
  • 6Zhang L, Wang Y. The shape of posterior corneal surface in normal, post-LASIK, and post-epi-LASIK eyes[J]. Invest Ophthalmol Vis Sei, 2010,51(7):3468-3475. DOI: 10.1167/ iovs.09-4811.
  • 7Grewal DS, Brar GS, Grewal SP. Posterior corneal elevation after LASIK with three flap techniques as measured by Pentacam[J]. J Refract Surg, 2011, 27(4): 261-268. DOI: 10.3928/1081597X-20100618-01.
  • 8Ozulken K, Cabot F, Yoo SH. Applications of femtosecand lasers in ophthalmic surgery[J]. Expert Rev Med Devices, 2013, 10(1): 115-124. DOI: lO.1586/erd.12.59.
  • 9Lee DH, Seo S, Jeong KW, et al. Early spatial changes in the posterior corneal surface after laser in situ keratomileusis[J]. J Cataract Refract Surg, 2003,29(4):778-784.
  • 10Peacock LW, Slade SG, Martiz J, et al. Ocular integrity after refractive procedures[J]. Ophthalmology, 1997, 104(7): 1079- 1083.