摘要
直流式整流罩空调在夏季高温、高湿、高盐雾环境中,存在制冷量有台阶、热工影响因素多、受环境影响大、响应特性差等问题,对此展开分析,提出了比例积分微分(Proportion-al Integral Derivative,PID)控制、温湿度解耦、制冷量台阶处理等空调控制策略,并对其进行试验验证,结果表明该措施有效。采用该控制策略对航天器进行环境保障,满足航天器对火箭整流罩内的温湿度要求。
An analysis is conducted on the problems of step cooling capacity,multiple thermal influencing factors,significant environmental impact,and poor response characteristics of the DC fairing air conditioning system,facing high temperature,high humidity,and high salt mist environments in summer.Based on this analysis,the air conditioning control strategies such as proportional integral derivative(PID)control,temperature and humidity decoupling,step cooling capacity treatment are proposed.Experimental verification is conducted on the control strategy,and the results showed that this measure was effective and feasible.It can effectively alleviate the step problem of air conditioning cooling capacity.The control strategy has been adopted to provide environmental protection for spacecraft,meeting the temperature and humidity requirements of the spacecraft for the rocket fairing.
作者
韦康
俞少行
陈宾毅
王杰
白玥
WEI Kang;YU Shaoxing;CHEN Binyi;WANG Jie;BAI Yue(Xichang Satellite Launch Center,Wenchang 571333,China)
出处
《宇航总体技术》
2024年第3期9-13,共5页
Astronautical Systems Engineering Technology
关键词
整流罩空调
制冷量台阶
PID控制
温湿度解耦
Fairing air conditioning
Cooling capacity step
PID control
Temperature and humidity decoupling