期刊文献+

基于非齐次泊松过程的高压断路器剩余电寿命预测及可靠性分析

Residual Electrical Lifetime Prediction and Reliability Analysis of High-voltage Circuit Breakers Based on Nonhomogeneous Poisson Process
下载PDF
导出
摘要 高压断路器可保护电力设备和电网免受过电流和短路的损害,其正常运行对于特高压线路来说至关重要。从高压断路器相对电寿命曲线入手,分情况建立了断路器电触头可靠性数学模型,基于非齐次泊松过程对可靠性模型进行仿真验证,获取了更加符合实际退化过程的可靠性模型,实现了断路器剩余电寿命及可靠性值的定量预测,为断路器运行状态评估、故障诊断及检修策略制定提供了借鉴和参考。 High-voltage circuit breakers play a crucial role in protecting power equipment and power grids from overcurrent and short-circuit damage,especially for extra-high-voltage lines.This paper establishes a mathematical model for the reliability of circuit breaker electrical contacts in various scenarios,starting from the relative electrical lifetime curve of high-voltage circuit breakers.The reliability model is then simulated and verified using the nonhomogeneous Poisson process to get better alignment with the actual degradation process.The results of this study enable quantitative prediction of residual electrical lifetime and reliability of circuit breakers,and provide valuable insights for operational state assessment,fault diagnosis and overhaul strategy formulation with respect to high-voltage circuit breakers.
作者 郑彦斌 宋朝晖 王园园 郭诚 冯继亮 常艳 蔡志强 贾栋 ZHENG Yanbin;SONG Chaohui;WANG Yuanyuan;GUO Cheng;FENG Jiliang;CHANG Yan;CAI Zhiqiang;JIA Dong(Xi′an XK Electric Power Equipment Intelligent Service Co.,Ltd.,Xi′an 710077,China;Northwest Branch of State Grid Corporation of China,Xi′an 710048,China;Xi′an XD Switchgear Electric Co.,Ltd.,Xi′an 710077,China;Northwestern Polytechnical University,School of Mechanical Engineering,Xi′an 710072,China)
出处 《电工技术》 2024年第11期199-203,共5页 Electric Engineering
基金 西安西开电力装备智慧服务有限公司研究项目“基于可靠性的800 kV断路器整机模型构建”(编号DK2304)。
关键词 高压断路器 非齐次泊松过程 电寿命 可靠性建模 high-voltage circuit breaker nonhomogeneous Poisson process electrical lifetime reliability modeling
  • 相关文献

参考文献3

二级参考文献70

共引文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...