期刊文献+

核电厂液态流出物中锶-89、锶-90、铁-55、铁-59和镍-63的联合快速分析方法

A combined rapid analytical method for strontium-89,strontium-90,iron-55,iron-59 and nickel-63 in liquid effluent of nuclear power plant
下载PDF
导出
摘要 锶-89、锶-90、铁-55、铁-59和镍-63是核电厂液态流出物中重点关注的核素。本建立了一种联用四级树脂柱快速分析液态流出物样品中锶-89、锶-90、铁-55、铁-59和镍-63的方法,该方法通过阳离子交换树脂富集样品中的阳离子,再依次通过锶树脂分离和纯化锶、TRU树脂分离和纯化铁、镍树脂分离和纯化镍,用电感耦合等离子体发射光谱仪测定化学回收率,用液体闪烁谱仪测定放射性计数率,计算出样品中各核素的活度浓度。典型条件下,样品量为1.0 L,测量时间为30 min,其方法探测下限可达到:锶-89为0.07 Bq/L、锶-90为0.05 Bq/L,铁-55为0.34 Bq/L,铁-59为0.11 Bq/L,镍-63为0.16 Bq/L。 Strontium-89,strontium-90,iron-55,iron-59 and nickel-63 are the major radionuclides concerned in liquid effluent of nuclear power plant.In this study,a method for rapid analysis of strontium-89,strontium-90,iron-55,iron-59 and nickel-63 in liquid effluent by four-stage resin column was established.The cation in the sample was enriched by cation exchange resin;and then strontium was separated and purified by strontium resin;iron was separated and purified by TRU resin;nickel was separated and purified by nickel resin.The chemical recovery rate was determined by ICP-OES;radioactive counting rate was determined by LSC;and then the activity concentration of each nuclide in the sample was calculated.Under typical conditions,the amount of sample is 1.0 L,and the measurement time is 30 min,the minimum detectable activity can reach 0.07 Bq/L for strontium-89,0.05 Bq/L for strontium-90,0.34 Bq/L for iron-55,0.11 Bq/L for iron-59,and 0.16 Bq/L for nickel-63.
作者 方春鸣 姜冬 郭小翠 莫念 FANG Chunming;JIANG Dong;GUO Xiaocui;MO Nian(Shandong Nuclear Power Co.Ltd.,Shandong Yantai 265100)
出处 《辐射防护》 CAS CSCD 北大核心 2024年第5期469-475,共7页 Radiation Protection
关键词 液态流出物 锶-89、锶-90、铁-55、铁-59和镍-63 联合快速分析 分离富集 液闪计数法 liquid effluent strontium-89,strontium-90,iron-55,iron-59 and nickel-63 combined rapid analysis separation and enrichment liquid scintillation counting
  • 引文网络
  • 相关文献

参考文献2

二级参考文献12

  • 1HORWITZ E P, CHIARIZIA R, DIETZ M L. A novel strontium-selective extraction chromato graphic resin[J]. Solvent Extr Ion Exc, 1992, 10(2): 313-336.
  • 2KIM C K, AL-HAMWI A, TOERVENYI A, et al. Validation of rapid methods for the determination of radiostrontium in milk[J]. Appl Radiat Isotopes, 2009, 67(5):786-793.
  • 3ISO 13160-2012 Water quality: Strontium 90 and strontium 89: Test methods using liquid scintillation counting or proportional counting [S]. Switzerland: ISO, 2012.
  • 4ASTM D5811-2008 Standard test method for strontium-90 in water[S]. US: ASTM, 2008.
  • 5LANDSTETTER C, WALLNER G. Determination of strontium-90 in deer bones by liquid scintillation spectrometry after separation on Srspecific ion exchange columns[J]. J Environ Radioactiv, 2006, 87(3): 315-324.
  • 6GB6766-1986水中锶-90放射化学分析方法二:(2-乙基己基)磷酸萃取色层法[S].北京:中国标准出版社,1986.
  • 7翟秀芳,李伟平,田梅,等.^90Sr的液闪谱仪测量方法研究[C]//第十六届全国核电子学与核探测技术学术年会.北京:中国核学会核电子学与核探测技术分会,2012:180-189.
  • 8Product sheet: GoldStar LT2 cocktail[EB/OL] [2014-03 12]. http://www.triskem-internation al. com/iso_album/ft_goldstarlt2_en_120103.pdf.
  • 9Rapid simultaneous determination of ^89Sr and ^90Sr in milk: A procedure using cerenkov and scintil- lation counting, IAEA/AQ/27 [R]. Vienna: IAEA, 2013.
  • 10叶宏生,丁声耀,容超凡.放射性分析手册[M].2版.北京:原子能出版社,2006.

共引文献8

;
使用帮助 返回顶部