摘要 The degradation behavior of biodegradable Mg alloys has become a research hotspot in the fields about biodegradable metallic materials.While the most of the related publications mainly focused on the degradation rate of Mg-based materials,but rare to care about the changes of their mechanical properties during the immersion period,which can significantly affect their service performance.The link between residual strength and Mg degradation is not appreciated enough.In this work,a series media were constructed based on Hanks’solution,the effects of inorganic ions on the degradation rate and mechanical integrity of Mg-Zn-Y-Nd alloy were investigated.The results indicated that the degradation behavior of Mg alloy was mainly controlled by degradation products and there is no direct correspondence between the degradation rate change and mechanical integrity of Mg alloy.The relevant findings are beneficial for selecting the monitoring index in Mg corrosion tests and evaluating the service reliability of Mg alloys for biomedical applications.
出处 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第9期3661-3674,共14页 镁合金学报(英文)
基金 support from the Na-tional Key Research and Development Program of China(2021YFC2400703) the Key Projects of the Joint Fund of the National Natural Science Foundation of China(U1804251) support from Natural Science Foundation of Henan Provincial(222300420309).
  • 相关文献

参考文献5

二级参考文献76

  • 1WITTE F, KAESE V, HAFERKAMP H, SWITZER E, MEYER-LINDENBERG A, WIRTH C J, WlNDHAGEN H. In vivo corrosion of four magnesium alloys and the associated bone response [J]. Biomaterials, 2005, 26(17): 3557-3563.
  • 2XU L, YU G, ZHANG E, PAN F, YANG K. In vivo corrosion behavior of Mg-Mn-Zn alloy for bone implant application [J]. Journal of Biomedical Materials Research: Part A, 2007, 83(3): 703-711.
  • 3WAKSMAN R, PAKALA R, KUCHULAKANTI P K, BAFFOUR R, HELLINGA D, SEABRON R, TIO F O, WITTCHOW E, HARTWIG S, HARDER C. Safety and efficacy of bioabsorbable magnesium alloy stents in porcine coronary arteries [J]. Catheterization and Cardiovascular Interventions, 2006, 68(4): 607-617.
  • 4PEUSTER M, HESSE C, SCHLOO T, F1NK C, BEERBAUM P, von SCHNAKENBURG C. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta [J]. Biomaterials, 2006, 27(28): 4955-4962.
  • 5PEUSTER M, WOHLSEIN P, BRIJGMANN M, EHLERDING M, SEIDLER K, FINK C, BRAUER H, FISCHER A, HAUSDORF G. A novel approach to temporary stenting: Degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into new zealand white rabbits [J]. Heart, 2001, 86(5): 563.
  • 6WAKSMAN R O N, PAKALA R, BAFFOUR R, SEABRON R, HELLINGA D, TIO F O. Short-term effects of biocorrodible iron stents in porcine coronary arteries [J]. Journal of Interventional Cardiology, 2008, 21(1): 15-20.
  • 7ZARTNER P, CESNJEVAR R, SINGER H, WEYAND M. First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby [J]. Catheterization and Cardiovascular Interventions, 2005, 66(4): 590-594.
  • 8ERBEL R, DI MARIO C, BARTUNEK J, BONNIER J, de BRUYNE B, EBERLI F R, ERNE P, HAUDE M, HEUBLEIN B, HORRIGAN M. Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: A prospective, non-randomised multicentre trial [J]. The Lancet, 2007, 369(9576): 1869-1875.
  • 9DI MARIO C, GRIFFITHS H U W, GOKTEK1N O, PEETERS N, VERBIST J A N, BOSIERS M, DELOOSE K, HEUBLEIN B, ROHDE R, KASESE V. Drug-eluting bioabsorbable magnesium stent [J]. Journal ofinterventional cardiology, 2004, 17(6): 391-395.
  • 10SCHRANZ D, ZARTNER P, MICHEL-BEHNKE I, AKIN'FORK H. Bioabsorbable metal stents for percutaneous treatment of critical recoarctation of the aorta in a newborn [J]. Catheterization and Cardiovascular Interventions, 2006, 67(5): 671-673.