期刊文献+

Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults 被引量:2

Intraexaminer repeatability and agreement in stereoacuity measurements made in young adults
下载PDF
导出
摘要 AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24 h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability(COR): ±13 and±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted.In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby(COR: ±69s arc)and Randot(COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.CONCLUSION:Therepeatabilityofstereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably. AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus.METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24 h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision.RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability(COR): ±13 and±12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted.In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby(COR: ±69s arc)and Randot(COR: ±72s arc). In both groups, the TNO test showed poorest agreement with the other tests.CONCLUSION:Therepeatabilityofstereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第2期374-381,共8页 国际眼科杂志(英文版)
基金 Supported by the Direction General of Universities and Research(DGUI)of the Community of Madrid(No.CCG10-UCM/BIO-4889)
关键词 STEREOACUITY REPEATABILITY AGREEMENT tereopsis stereoacuity repeatability agreement tereopsis
  • 相关文献

同被引文献18

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部