期刊文献+

循环水旁滤中试研究 被引量:3

Pilot Scale Experiment of Recycle Water Filtration
下载PDF
导出
摘要 目前所使用的纤维束过滤器经多次检测出水浊度往往大于进水浊度,其主要原因是纤维束已受污染,并且很难冲洗干净。因此选用高效流砂过滤器进行循环水旁滤处理,实验表明在使用高效流砂过滤器时,投加聚合氯化铝(PAC)处理效果非常理想。在PAC投量为5~10 mg/L时,平均去除率达到83%,平均进水浊度7.05NTU,平均出水浊度为1.2NTU。完全能够满足旁滤的要求。 The outlet turbidity is higher than the inlet turbidity of the fiber bundle filters which are using present in most cases. The reason is that the fiber bundle of the fiber bundle filters are too polluted to be cleaned up. After applying the high effective sandflo filter system to treat recycle water, we discovered when PAC using 5~10 mg/L, the removal rate of turbidity is 83%, the inlet of filtration NTU is 7.05 and the outlet of filtration NTU is 1.2. The result can meet the equipment of the process completely.
作者 夏菁
出处 《油气田环境保护》 CAS 2003年第2期26-27,共2页 Environmental Protection of Oil & Gas Fields
关键词 循环水 旁滤 纤维束过滤器 浊度 絮凝剂 高效流砂过滤器 recycles water,fiber bundle filter, high effective sandflo filter, turbidity, flocculant
  • 相关文献

参考文献2

共引文献11

同被引文献38

  • 1Kramer,J.P.,Wouters,J.W.,Rosmalen,Pvan.帕克活性生物砂滤脱氮的四年运行经验[J].水工业市场,2009(3):63-66. 被引量:3
  • 2刘金凤,丁仁泉,李宏.循环水旁滤系统的设计与改进[J].当代化工,2005,34(1):67-69. 被引量:4
  • 3王东,马景辉,张红丽,丛林.DynaSand活性砂过滤器在市政中水回用中的应用[J].工业水处理,2006,26(9):59-61. 被引量:25
  • 4孟玉.连续砂过滤工艺及其在水处理中的应用[J].中国资源综合利用,2006,24(10):21-23. 被引量:5
  • 5Schauer P, Rectanus R,deBarbadillo C,et al. Pilot tes- ting of upflow continuous backwash filters for tertiary denitrification and phosphorus removal[ A]. Proceedings of the Water Environment Federation (WEFTEC 2006: Session 61 through session 70) [C]. US :Water Environ- ment Federation ,2006.
  • 6Natvik Olav,Nutt Stephen G,Smith Steven,et al. Achie- ving low effluent total phosphorus concentrations -how low can we go? [ A ]. Proceedings of the Water Envi- ronment Federation( WEFTEC 2005 : Session 71 through session 80) [ C ]. US: Water Environment Federation, 2005.
  • 7Hans Wouters,Wesley J-nes. Moving bed tertiary biofil- ters - an upgrade for WwTWs [ J]. Filtr Sep,2004,41 (10) :25 -27.
  • 8Stephen Hinton. 25 years of continuous sand filtration - uninterrupted [ EB/OL]. http://www, sldtonline, corn, 2004 - 06 - 30.
  • 9Kramer J P,Wouters J W. DynaSand filtration for drink- ing-water production[J]. J Water Supply Res Technol, 1993,42(2) :97 - 104.
  • 10Heinonen-Tanski H, Juntunen P, Rajala R,et al. Costs of tertiary treatment of municipal wastewater by rapid sand filter with coagulants and UV [J]. Water Sci Tech- no1,2003,3 (4) : 145 - 152.

引证文献3

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部