期刊文献+

Three dimensional finite element analysis of anatomic distal radius Nitinol memory connector treating distal radius fracture 被引量:4

Three dimensional finite element analysis of anatomic distal radius Nitinol memory connector treating distal radius fracture
下载PDF
导出
摘要 Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector (DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14.66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa,and the stress of compression part was 20-40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing. Objective: To study the memory biomechanical character of anatomic distal radius Nitinol memory connector ( DRMC) in treating distal radius fracture. Methods: Establishing three dimensional model and finite element analysis, we calculated the stress in and around the fracture faces when distal radius fracture was fixated with DRMC. Results: Axial holding stress produced by holding part of DRMC on distal radius was 14. 66 MPa. The maximum stress of holding part was 40-70 MPa, the minimum stress was 3-7 MPa, and the stress of compression part was 20 - 40 MPa. Conclusion: The distribution of stress produced by DRMC around the fracture line is reasonable, and axial holding stress can help stabilize fracture during earlier period. The existence of longitudal compression and memory effect can transfer fixated disused section into developed section and enhance fracture healing.
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第4期226-229,共4页 中国人民解放军军医大学学报(英文版)
关键词 distal radius Nitinol memory connector distal radius fracture 3 dimensional finite element analysis memory biomechanics 三维有限元分析 桡骨远端镍钛合金记忆连接器 桡骨远端骨折 生物力学
  • 相关文献

参考文献1

  • 1[7]Claes Le, Heigele CA, Neidlinger WC et al. Effects of mechanical factors on the fracture healing process [J]. Clin Orthop, 1998; 355 (Suppl): S132.

同被引文献13

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部