期刊文献+

Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures 被引量:2

Reliability of the pronator quadratus fat pad sign to predict the severity of distal radius fractures
下载PDF
导出
摘要 AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures. AIM To evaluate the reliability of pronator quadratus fat pad sign to detect distal radius fracture and to predict its severity.METHODS Retrospectively we identified 89 consecutive patients(41 female, mean age 49 ± 18 years) who had X-ray(CR) and computed tomography(CT) within 24 h following distal forearm trauma. Thickness of pronator quadratus fat pad complex(PQC) was measured using lateral views(CR) and sagittal reconstructions(CT). Pearson's test was used to determine the correlation of the PQC thickness in CR and CT. A positive pronator quadratus sign(PQS) was defined as a PQC > 8.0 mm(female) or > 9.0 mm(male). Frykman classification was utilized to assess the severity of fractures.RESULTS Forty-four/89 patients(49%) had a distal radius fracture(Frykman Ⅰ n = 3, Ⅱ n = 0, Ⅲ n = 10, Ⅳ n = 5, Ⅴ n = 2, Ⅵ n = 2, Ⅶ n = 9, Ⅷ n = 13). Mean thickness of the PQC thickness can reliably be measured on X-ray views and was 7.5 ± 2.8 mm in lateral views(CR), respectively 9.4 ± 3.0 mm in sagittal reconstructions(CT), resulting in a significant correlation coefficientof 0.795. A positive PQS at CR was present in 21/44 patients(48%) with distal radius fracture and in 2/45 patients(4%) without distal radius fracture, resulting in a specificity of 96% and a sensitivity of 48% for the detection of distal radius fractures. There was no correlation between thickness of the PQC and severity of distal radius fractures.CONCLUSION A positive PQS shows high specificity but low sensitivity for detection of distal radius fractures. The PQC thickness cannot predict the severity of distal radius fractures.
出处 《World Journal of Radiology》 CAS 2017年第9期359-364,共6页 世界放射学杂志(英文版)(电子版)
  • 相关文献

同被引文献25

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部