期刊文献+

Predictive factors for the failure of endoscopic stent-instent self-expandable metallic stent placement to treat malignant hilar biliary obstruction 被引量:3

Predictive factors for the failure of endoscopic stent-instent self-expandable metallic stent placement to treat malignant hilar biliary obstruction
下载PDF
导出
摘要 AIM To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents(SEMSs). METHODS This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography(ERCP) procedures between the two groups.RESULTS The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices(ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve(sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. CONCLUSION A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement. AIM To investigate the factors predictive of failure when placing a second biliary self-expandable metallic stents(SEMSs). METHODS This study evaluated 65 patients with an unresectable malignant hilar biliary obstruction who were examined in our hospital. Sixty-two of these patients were recruited to the study and divided into two groups: the success group, which consisted of patients in whom a stent-in-stent SEMS had been placed successfully, and the failure group, which consisted of patients in whom the stent-in-stent SEMS had not been placed successfully. We compared the characteristics of the patients, the stricture state of their biliary ducts, and the implemented endoscopic retrograde cholangiopancreatography(ERCP) procedures between the two groups.RESULTS The angle between the target biliary duct stricture and the first implanted SEMS was significantly larger in the failure group than in the success group. There were significantly fewer wire or dilation devices(ERCP catheter, dilator, or balloon catheter) passing the first SEMS cell in the failure group than in the success group. The cut-off value of the angle predicting stent-in-stent SEMS placement failure was 49.7 degrees according to the ROC curve(sensitivity 91.7%, specificity 61.2%). Furthermore, the angle was significantly smaller in patients with wire or dilation devices passing the first SEMS cell than in patients without wire or dilation devices passing the first SEMS cell. CONCLUSION A large angle was identified as a predictive factor for failure of stent-in-stent SEMS placement.
出处 《World Journal of Gastroenterology》 SCIE CAS 2017年第34期6273-6280,共8页 世界胃肠病学杂志(英文版)
基金 Supported by Department of Gastroenterology,Fukushima Medical University,School of Medicine
关键词 Endoscopic stent-in-stent self-expandable metallic stent placement Predictive factor Endoscopic retrograde cholangiopancreatography Malignant hilar biliary obstruction Self-expandable metallic stent 内视镜的 stent-in-stent 自我可扩充的金属性的 stent 放置;预兆的因素;内视镜后退 cholangiopancreatography;恶意的 hilar 胆汁的阻塞;自我可扩充的金属性的 stent
  • 相关文献

同被引文献13

引证文献3

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部