摘要
本通过水泥软练设备测量仪、电子秒表和数显卡尺对水泥净浆搅拌机的转速、搅拌工作时间和搅拌叶片外沿直径进行直接测量,以水泥软练设备测量仪、电子秒表和数显卡尺的读数为测量结果,并对示值误差测量结果的影响因素进行了分析,最终给出示值误差测量结果的不确定度。
This experiment was designed to directly test the rotational speed,duration of the stirring process and the outer diameter of a cement paste mixer by a measuring instrument for cement bright degumming equipment,an electronic timer and a digital caliper;The measured results were based on the readings of the above-mentioned measuring devices,factors to affect the derivations of the measured data were analyzed,and thereafter,the uncertainties of the measured data were calculated.
作者
卓焕权
Zhuo Huanquan(Guangdong Shanwei Quality Metrology Supervision Testing Institute,Shanwei 516611)
出处
《仪器仪表标准化与计量》
2019年第6期40-42,共3页
Instrument Standardization & Metrology
关键词
水泥净浆搅拌机
转速
示值误差
Cement Paste Mixer
Rotational Speed
Indication Error