摘要
在离心式氮气压缩机组调试过程中,遇到了变速齿轮箱轴承振动值超标、高压缸轴承振动值超标、碳环密封碎裂、推力瓦温度高报警等影响机组正常启动、运行的现象,本文总结了调试过程中遇到的问题及采取的应对方法。
In the commissioning process of centrifugal nitrogen compressor, there are some problems affecting the normal start-up and operation of the unit, such as the vibration value of the variable speed gearbox bearing and the high pressure cylinder bearing exceeding the standard, the carbon ring seal is broken, and the high temperature alarm of the thrust pad. This paper summarizes the problems encountered in the commissioning process and the countermeasures taken.
作者
展振忠
吴兴典
孙传驰
ZHAN Zhenzhong;WU Xingdian;SUN Chuanchi(Shandong Runyin Biochemical Co.,Ltd.,Dongping 271500,Shandong Province)
出处
《氮肥技术》
CAS
2022年第4期44-47,共4页
Nitrogenous Fertilizer Technology
关键词
离心式压缩机
振动
碳环密封
推力瓦块
centrifugal compressor
vibration
carbon ring seal
thrust pad