摘要
建立了一种采用Tenax TA固体吸附/热脱附与气相色谱仪联用测定环境空气中苯系物的方法;该方法校准曲线线性良好,采样体积为1 L时,各组分检出限为2.7×10-4~4.7×10-4mg/m3;该方法灵敏度高,精确可靠,操作便捷,适用于环境空气中苯系物的测定。
In this paper,a method for determining benzene series in ambient air by Tenax TA solid adsorption/thermal desorption combined with gas chromatography was established.The calibration curve of this method has good linearity.When the sampling volume is 1 L,the detection limit of each component is 2.7×10-4 to 4.7×10-4 mg/m3.This method is sensitive,accurate,reliable and easy to operate,and it is suitable for the determination of benzene series in ambient air.
作者
赵乾
ZHAO Qian(Shanxi Transportation Environmental Protection Center(Co.,Ltd.),Taiyuan,Shanxi 030032,China)
出处
《山西交通科技》
2020年第3期114-116,127,共4页
Shanxi Science & Technology of Transportation
关键词
环境空气
苯系物
热脱附
气相色谱
ambient air
benzene series
thermal desorption
gas chromatography