摘要 【目的】探讨全身成像三维量化(general imaging 3-dimensional quantification,GI3DQ)评价左心室收缩功能的价值。【方法】选取45例患者,用实时三维(RT-3D)超声心动图采集心尖四腔心全容积图像,将其导入GI3DQ三维图像工作站脱机测量左心室舒张末期容积(left ventricular end diastolic volume,LVEDV)和左心室收缩末期容积(left ventricular end systolic volume,LVESV),得出射血分数(ejection fraction,EF);MRI测量LVEDV和LVESV,并计算左心室每搏量(left ventricular stroke volume,LVSV)和EF。GI3DQ和MRI的测值行相关性分析。【结果】GI3DQ和MRI评价左心室收缩功能,EF相关性为r=0.87,GI3DQ和MRI两种方法行一致性分析,差异无统计学意义(P>0.05)。【结论】GI3DQ可对左心室收缩功能进行准确的定量评估,为临床评价左心室收缩功能提供了更加准确、简便的新方法。 【Objective】To explore the value of general imaging 3-dimensional quantification(GI3DQ)in evaluating left ventricular systolic function.【Methods】45 patients were selected to measure the left ventricular end diastolic volume(LVEDV)and end systolic volume(LVESV)so as to obtain the ejection fraction(EF),whose full volume image of apical four chamber heart was collected by realtime three-dimensional(RT-3D)echocardiography and full volume image of three-dimensional apical four chamber heart was imported by GI3DQ three-dimensional imaging.The work station measured LVEDV and LVESV offline to get EF value.LVEDV and LVESV were measured by MRI,and left ventricular stroke volume(LVSV)and LVEF were calculated.The correlation between GI3DQ and MRI was analyzed.【Results】The correlation of EF between GI3DQ and MRI was as follows,r=0.87.There was no significant difference between GI3DQ and MRI(P>0.05).【Conclusion】GI3DQ can evaluate left ventricular systolic function accurately and quantitatively,which provides a more accurate and simple new method for clinical evaluation of left ventricular systolic function.
作者 唐海霞 林凌 钟文津 刘丽莉 TANG Hai-xia;LIN Ling;ZHONG Wen-jin;LIU Li-li(Department of ultrasound,Hainan General Hospital,Hainan Affiliated Hospital of Hainan Medical University,Haikou 570311,China)
出处 《武警后勤学院学报(医学版)》 CAS 2020年第11期20-23,共4页 Journal of Logistics University of PAP(Medical Sciences)
关键词 全身成像三维量化 超声心动描计术 左心室收缩功能 磁共振成像 General imaging 3-dimensional quantification Echocardiography Left ventricular systolic function Magnetic resonance imaging
  • 相关文献

参考文献1

二级参考文献11

  • 1Zoghbi WA, Enriquez-Sarano M, Foster E, et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography [J]. J Am Soc Echocardiogr, 2003, 16(7) :777-802.
  • 2Thavendiranathan P, Liu S, Datta S, et al. Automated quantification of mitral inflow and aortic outflow stroke volumes by three-dimensional real-time volume color-flow Doppler transthoracic echocardiography: comparison with pulsed-wave Doppler and cardiac magnetic resonance imaging [ J ]. J Am Soc Echocardiogr, 2012, 25 ( 1 ) :56-65.
  • 3Skaug TR, Amundsen BH, Hergum T, et al. Quantification of aortic regurgitation using high-pulse repetition frequency three- dimensional colour Doppler. Eur Heart J Cardiovasc Imaging, 2014, 15(6) :615-622.
  • 4Wang W, Lin Q, Wu W, et al. Quantification of mitral regurgitation by general imaging three-dimensional quantification: feasibility and accuracy [ J 1. J Am Soc Echocardiogr, 2014, 27 (3) :268-276.
  • 5Pouleur AC, le Polain de Waroux JB, Goffinet C, et al. Accuracy of the flow convergence method for quantification of aortic regurgitation in patients with central, versus eccentric jets[J]. Am J Cardiol, 2008, 102(4) :475-480.
  • 6Lancellotti P, Tribouilloy C, Hagendorff A, et al. European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1 : aortic and pulmonary regurgitation (native valve disease ) [ J ]. Eur J Eehocardiogr, 2010, 11 (3) :223-244.
  • 7Lancellotti P, Tribouilloy C, Hagendorff A, et al. Recommendations for the echocardiographic assessment of native valvular regurgitation: an executive suranmry from the European Association of Cardiovascular Imaging[ J]. Eur Heart J Cardievasc Imaging, 2013, 14(7):611-644.
  • 8Lang RM, Badano LP, Tsang W, et al. EAE/ASE recommendations for image acquisition and display using three- dimensional echocardiography [ J ]. J Am Soc Echocardiogr, 2012, 25(1) :3-46.
  • 9Ewe SH, Delgado V, van der Geest R, et al. Accuracy of three- dimensional versus two-dimensional echocardiography for quantification of aortic regurgitation and validation by three- dimensional three-directional velocity-encoded magnetic resonance imaging[J]. Am J Cardiol, 2013, 112(4) :560-566.
  • 10Cawley PJ, Hamilton-Crag C, Owens DS, et al. Prospective comparison of valve regurgitation quantitation by cardiac magnetic resonance imaging and transthoraeie echocardiography [ J ]. Circ Cardiovasc Imaging, 2013, 6 ( 1 ) :48-57.

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部