摘要 在某天然气长输管道工程中发现相控阵超声检测(PAUT)与射线检测对未熔合缺陷的检测结果不吻合,结合检测工作中的经典案例以及两种检测方法原理得出结论:相控阵超声检测和射线检测结合使用能够有效提高未熔合的检出率。 It is found that the Phase array ultrasonic testing(PAUT)and the X-ray testing of non-fusion defects are not in agreement in a long gas pipeline project.Combining the classic cases in the testing work and the principle of two testing methods,It is concluded that the testing rate of non-fusion can be improved by the combination of phase array ultrasonic testing and X-ray testing.
作者 程文虎 李志洪 谢宝坤 王海环 CHENG Wenhu;LI Zhihong;XIE Baokun;WANG Haihuan(Sinopec Hebei Jiantou Natural Gas Co.,Ltd.,Shijiazhuang 050001,China;Shandong Kejie Engineering Testing Co.,Ltd.,Jinan 250101,China)
出处 《无损探伤》 2020年第2期41-43,共3页 Nondestructive Testing Technology
关键词 长输管道 相控阵超声检测(PAUT) 射线检测 未熔合 Long pipeline Phased array ultrasound testing(PAUT) X-ray testing Lack of fusion