摘要 随着国网公司对智能变电站模块化建设的不断推进,钢框架结构形式得到广泛应用。变电站内的建筑物通常层高较高、基础埋深较大。短柱基础可有效减小底层柱的计算长度,满足底层抗侧刚度要求。结合工程实例,对单、多层钢框架结构采用不同高度及截面尺寸的短柱基础与按以短柱顶为嵌固端进行简化计算的分析比较,总结采用短柱基础的钢框架设计方法,为模块化变电站标准化设计积累经验。 With the continuous promotion of modular construction of Smart Substation by State Grid Corporation of China,steel frame structure is widely used.The buildings in substations are usually of high floor height and deep foundation.The puncheon foundation can effectively reduce the calculation length of the bottom column and meet the requirements of the bottom lateral stiffness.Combined with the engineering example,the simplified calculation analysis and comparison of steel frame structure with puncheon foundation of different height and size and with puncheon top as embedded end are carried out,and the design method of steel frame with puncheon foundation is summarized so as to accumulate experience for standardized design of modular substation.
作者 徐雁翎 XU Yanling(Liaoning Electric Power Survey and Design Institute Co.,Ltd.,CECG.Shenyang 110179,China)
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2021年第S02期149-152,共4页 Engineering Journal of Wuhan University
关键词 模块化变电站 钢框架结构 短柱基础 modular substation steel frame structure puncheon foundation
  • 相关文献

参考文献6

二级参考文献16

  • 1袁燕.如何确定短柱基础短柱截面的大小[J].四川建筑,2004,24(6):52-52. 被引量:1
  • 2党昱敬.消除液化土沉陷措施灌注桩法与振冲碎石桩法设计应用探讨[J].建筑科学,2006,22(2):94-98. 被引量:7
  • 3中国建筑西北设计院.结构专业统一技术措施(XBG001)[M].,1992..
  • 4刘大海 钟锡根 杨翠如著.单层与多层建筑抗震设计[M].陕西科学技术出版社,1997..
  • 5[4]清华大学.混凝土结构及砌体结构.北京:清华大学出版社,2003
  • 6GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 7刘大海,钟锡根,杨翠如.单层与多层建筑抗震设计[M].西安:陕西科学技术出版社,1997.
  • 8GB50007-2002.建筑地基基础设计规范[S].[S].,..
  • 9GB50011-2001.建筑抗震设计规范[S].[S].,..
  • 10GB50007-2011建筑地基基础设计规范[s].北京:中国建筑工业出版社,2012.

共引文献9

同被引文献1

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部