期刊文献+

Robust subsynchronous interaction damping controller for DFIG-based wind farms 被引量:4

Robust subsynchronous interaction damping controller for DFIG-based wind farms
原文传递
导出
摘要 This paper proposes a robust controller to improve power system stability and mitigate subsynchronous interaction(SSI)between doubly-fed induction generator(DFIG)-based wind farms and series compensated transmission lines.A robust stability analysis is first carried out to show the impact of uncertainties on the SSI phenomenon.The uncertainties are mainly due to the changes in the power system impedance(e.g.,transmission line outages)and the variations of wind farm operating conditions.Then,using theμ-synthesis technique,a robust SSI damping controller is designed and augmented to the DFIG control system to effectively damp the SSI oscillations.The output signals of the supplementary controller are dynamically limited to avoid saturating the converters and to provide DFIG with the desired fault-ride-through(FRT)operation during power system faults.The proposed controller is designed for a realistic test system with multiple series capacitor compensated lines.The frequency of the unstable SSI mode varies over a wide range due to the changes in power system topologies and wind farm operating conditions.The performance of the proposed controller is verified through electromagnetic transient(EMT)simulations using a detailed wind farm model.Simulation results also confirm the grid compliant operation of the DFIG. This paper proposes a robust controller to improve power system stability and mitigate subsynchronous interaction(SSI) between doubly-fed induction generator(DFIG)-based wind farms and series compensated transmission lines.A robust stability analysis is first carried out to show the impact of uncertainties on the SSI phenomenon.The uncertainties are mainly due to the changes in the power system impedance(e.g.,transmission line outages) and the variations of wind farm operating conditions.Then,using the μ-synthesis technique,a robust SSI damping controller is designed and augmented to the DFIG control system to effectively damp the SSI oscillations.The output signals of the supplementary controller are dynamically limited to avoid saturating the converters and to provide DFIG with the desired fault-ride-through(FRT) operation during power system faults.The proposed controller is designed for a realistic test system with multiple series capacitor compensated lines.The frequency of the unstable SSI mode varies over a wide range due to the changes in power system topologies and wind farm operating conditions.The performance of the proposed controller is verified through electromagnetic transient(EMT)simulations using a detailed wind farm model.Simulation results also confirm the grid compliant operation of the DFIG.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2019年第6期1663-1674,共12页 现代电力系统与清洁能源学报(英文)
基金 supported by Canadian Network for Research and Innovation in Machining Technology and Natural Sciences and Engineering Research Council of Canada(No.10.13039/501100000038).
关键词 DOUBLY-FED induction generator(DFIG) Subsynchronous interaction(SSI) μ-synthesis ROBUST control Series CAPACITOR compensation Doubly-fed induction generator(DFIG) Subsynchronous interaction(SSI) μ-synthesis Robust control Series capacitor compensation
  • 相关文献

参考文献2

共引文献11

同被引文献50

引证文献4

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部