摘要
高层建筑结构嵌固端位置的确定对结构分析计算结果真实性和准确性有很大影响,正确合理地选取高层建筑的嵌固部位,不仅需满足规范所要求刚度比和相关抗震构造措施等要求,还应考虑到实际工程和场地条件复杂性。通过对高层结构嵌固端的分析和设计探讨,针对设计中存在的问题给出相关处理办法,为类似工程提供借鉴。
The determination of the location of the embedded end of a high-rise building structure has a great impact on the authenticity and accuracy of the structural analysis calculation results.Correct and reasonable selection of the embedded position of a high-rise building not only needs to meet the stiffness ratio required by the code and relevant seismic structural measures.Such requirements should also take into account the complexity of actual engineering and site conditions.This paper analyzes and designs the embedded ends of high-rise structures,and provides relevant solutions to the problems in the design,providing a reference for similar projects.
作者
李兴兵
雷雨润
Li Xing-bing;Lei Yu-run
出处
《建筑技术开发》
2020年第7期11-12,共2页
Building Technology Development
关键词
嵌固端
地下室顶板
刚度比
高层建筑
embedded end
basement roof
stiffness ratio
high-rise building