摘要
用离子色谱法,KOH流动相梯度洗脱,检测饮用水中氟化物、亚氯酸盐、溴酸盐、氯化物、二氯乙酸、亚硝酸盐、氯酸盐、硝酸盐、三氯乙酸、硫酸盐和草甘膦,各待测物质出峰相互无干扰,检出限分别为0.521、0.436、0.950、0.094、0.900、0.444、2.294、0.931、10.2、0.203和0.199 ppb,测定下限分别为2.1、1.7、3.8、0.4、3.6、1.8、9.2、3.7、40.8、0.8和0.8 ppb,精密度1.27%~3.81%,准确度83.1%~110.5%。
In the paper,fluoride,chlorite,bromate,chloride,dichloroacetic acid,nitrite,chlorate,nitrate,trichloroacetic acid,sulfate and glyphosate in drinking water are detected by ion chromatography with KOH mobile phase gradient elution.The peaks of the substances to be tested do not interfere with each other.The detection limits are 0.521,0.436,0.950,0.094,0.900,0.444,2.294,0.931,10.2,0.203,0.199ppb,The lower limit of determination is 2.1,1.7,3.8,0.4,3.6,1.8,9.2,3.7,40.8,0.8,0.8ppb respectively,the precision is 1.27%~3.81%,the accuracy is 83.1%~110.5%,which can be used for the detection of various items to be tested in drinking water and has certain practical value.
作者
甘晓娟
贾紫永
王杰
胡晓玲
黄抒
姚思佳
淳宇彤
GAN Xiaojuan;JIA Ziyong;WANG Jie;HU Xiaoling;HUANG Shu;YAO Sijia;CHUN Yutong(The Water Quality Monitoring Network of National Urban Water Supply Monitoring Station of Chongqing,Chongqing 400074,China;China Com munications Third Airlines(Chongqing)Ecological Restoration Research Institute Co.,Ltd.,Chongqing 400000,China)
出处
《给水排水》
CSCD
北大核心
2023年第S01期87-91,共5页
Water & Wastewater Engineering
关键词
离子色谱法
饮用水
二氯乙酸
三氯乙酸
草甘膦
Ion chromatography
Drinking water
Dichloroacetic acid
Trichloroacetic acid
Glyphosate