摘要
对《消防给水及消火栓系统技术规范》(GB 50974-2014)及《自动喷水灭火系统设计规范》(GB 50084-2017)中自动喷水灭火系统的设计进行了要点分析,对建筑中喷淋系统的分区、管材选择进行梳理,以及对自动喷水灭火系统在设计中忽视的问题进行重点分析,并结合具体的工程案例说明设计中应注意的问题以及解决办法。
This paper analyzed the key points of the design of sprinkler system in Technical code for fire protection water supply and hydrant system(GB 50974-2014)and Code for design of sprinkler system(GB 50084-2017),reviewed the zoning and pipe selection of sprinkler systems in buildings,and focused on the analysis of the problems overlooked in the design of automatic sprinkler systems.Also,this paper explained the problems that should pay attention to and the relevant solutions in design with specific engineering examples.
作者
潘庆
Pan Qing(Shanghai Urban Space Architectural Design Co.,Ltd.,Shanghai 200030,China)
出处
《给水排水》
CSCD
北大核心
2020年第S01期810-813,共4页
Water & Wastewater Engineering
关键词
喷淋系统
喷头
系统工作压力
设计工作压力
管材
Sprinkler systems
Sprinkler
Working pressure of the system
Design working pressure
Pipe materials