摘要 为研究装配式内置钢管混凝土异形柱框架节点的抗震性能,设计了3个足尺节点,变化参数为轴压比,通过斜向低周往复加载试验,分析其滞回性能、变形能力、耗能能力和刚度退化,结果表明:装配式内置钢管混凝土异形柱框架L形节点在斜向加载时破坏形式为梁端塑性铰破坏,满足“强柱弱梁”设计要求;试验滞回曲线饱满,当轴压比由0.2增加到0.4时,开裂、屈服和峰值荷载均增大,发生破坏时的层间位移角平均值为1/34。在轴压比0.2~0.4范围内,位移延性系数均大于1.0,等效黏滞阻尼系数均大于0.2,且随着轴压比增大两者变化均较小,达到破坏时的割线刚度平均值约为初始刚度的38.3%,节点具有较好的耗能和变形能力。 In order to study the seismic performance of prefabricated concrete-filled steel tubular special-shaped column frame joints,three full-size L-shaped joints with concrete-filled steel tubular special-shaped columns were designed.The variable parameter was the axial compression ratio.Through the oblique low-cycle reciprocating loading test,the hysteretic performance,deformation capacity,energy dissipation capacity,and stiffness degradation of specimens were analyzed.The results show that the failure mode of the L-shaped joints of the frame with prefabricated concrete-filled steel tubular special-shaped columns under oblique loading is plastic hinge failure at the beam end,which meets the design requirements of‘strong column and weak beam’.The hysteretic curve of the specimen is full.When the axial compression ratio increases from 0.2 to 0.4,the cracking,yield,and peak loads of the specimen increase,and the average value of the interlayer displacement angle when the failure occurs is 1/34.When the axial compression ratio is within the range of 0.2 to 0.4,the displacement ductility coefficient of specimens is greater than 1.0,and the equivalent viscous damping coefficient is greater than 0.2.The change in the aforementioned two indicators is minimal with the increase of the axial compression ratio,and the average value of the secant stiffness at the time of failure is about 38.3%of the initial stiffness,and the specimens show good energy dissipation and deformation capacities.
作者 武立伟 郭雪源 刘汉清 陈海彬 周中一 陈艳华 WU Liwei;GUO Xueyuan;LIU Hanqing;CHEN Haibin;ZHOU Zhongyi;CHEN Yanhua(Key Laboratory of Earthquake Engineering and Engineering Vibration,Institute of Engineering Mechanics,China Earthquake Administration,Harbin 150080,China;Hebei Earthquake Engineering Research Center,North China University of Science and Technology,Tangshan 063210,China;SASAC Metallurgical Authority Service Center,Beijing 100010,China)
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2023年第S01期120-128,共9页 Journal of Building Structures
基金 国家重点研发计划(2019YFC1509304) 中央引导地方科技发展资金项目(226Z4502G) 河北省自然科学基金项目(E2022209060,E2020209072)
关键词 框架L形节点 装配式异形柱 叠合梁 斜向加载试验 抗震性能 L-shaped frame joint assembled special-shaped column composite beam oblique loading test seismic behavior
  • 相关文献

参考文献12

二级参考文献116

共引文献289

同被引文献8

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部