摘要 欧规EN 1994-1-1中仅列入了双H形钢部分包覆钢-混凝土组合(PEC)构件的截面形式,但对其压弯承载力计算方法和截面构造都未予以明确规定。为此,设计了3类截面形式的正交双H形钢PEC柱试件,对其进行了压弯条件下的往复加载试验,并将试验结果与采用作者前期提出的单向压弯及双向压弯承载力计算方法的计算结果进行比较。结果表明:钢翼缘对混凝土有明显的约束作用;试件在单向压弯和双向压弯下具有相同的抗弯刚度和承载力,均表现出了良好的塑性变形能力和耗能性能,加强箍筋可以提高试件的延性;前期提出的压弯承载力计算方法得到的压弯承载力与试件结果相比偏于安全,而相比于欧洲规范EC4的计算方法又具有一定的经济性。 The EN1991-1-1 only introduces the cross-section form of intersecting H-shaped partially encased composite(PEC) members, but its calculation method and configuration are not specified clearly. To resolve this problem, three types of cross-section of intersecting H-shaped PEC columns were designed. The tests of five specimens were conducted under cyclic horizontal loading and constant axial compression. The experimental results are compared with the results obtained by the calculation method of the ultimate strength of cross-section proposed by the authors previously. The results show that the steel flange has obvious restraining effect on concrete;the specimen has the same bending stiffness and bearing capacity under uniaxial bending and biaxial bending;all specimens have good plastic deformation ability and energy dissipation performance, and the reinforcement of the stirrup can improve the ductility of the specimen. Compared with the test results, the flexural capacity obtained by the calculation method proposed by the author is relatively safe, and compared with the calculation results of European code EC4, it is more economical.
作者 宋世明 李杰 陈以一 詹欣欣 SONG Shiming;LI Jie;CHEN Yiyi;ZHAN Xinxin(College of Civil Engineering,Tongji University,Shanghai 200092,China)
出处 《建筑结构学报》 EI CAS CSCD 北大核心 2019年第S01期171-178,共8页 Journal of Building Structures
基金 科技部重点研发计划(2016YFC0701603).
关键词 部分包覆钢-混凝土构件 双H形钢主钢件 截面构造方式 拟静力试验 压弯性能 partially encased composite member intersecting H-shaped steel cross-section configuration quasi-static test performance under compression and bending
  • 相关文献

参考文献9

二级参考文献98

  • 1赵根田,王聊杨,冯超.薄柔H形钢部分包裹混凝土梁柱组合体抗震性能研究[J].建筑结构学报,2013,34(S1):96-101. 被引量:19
  • 2.GB50017-2003钢结构设计规范[S].北京:中国计划出版社,2003..
  • 3GB50011-2008建筑抗震设计规范[S].北京:中国建筑工业出版社.2008.
  • 4GB50011-2010建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
  • 5YB9082-2006钢骨混凝土结构技术规程[S].北京:冶金工业出版社,2006.
  • 6Muise J.Behaviour of simple framing connections topartially concrete encased H section columns[D].Toronto,Canada:University of Toronto.Dept.of CivilEngineering,2000.
  • 7Elnashai A S,Takanashai K,Elghazouli A Y,DowlingP J.Experimental behaviour of partially encasedcomposite beam-columns under cyclic and dynamicloads[J].Proceeding of the Institute of CivilEngineers:Structures and Buildings,1991,91(2):259-272.
  • 8Elnashai A S,Elghazouli A Y.Performance ofcomposite steel/concrete members under earthquakeloading:part 1:analytical model[J].EarthquakeEngineering and Structural Dynamics,1993,22(4):315-345.
  • 9Elghazouli A Y,Elnashai A S.Performance ofcomposite steel/concrete members under earthquakeloading:part 2:parametric studies and designconsiderations[J].Earthquake Engineering andStructural Dynamics,1993,22(4):347-368.
  • 10Elnashai A S,Broderick B M.Seismic resistance ofcomposite beam-columns in multi-story structures:part1:experimental studies[J].Journal of ConstructionSteel Research,1994,30(3):201-229.

共引文献153

同被引文献70

引证文献13

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部