期刊文献+

股骨颈前倾角测量方法的回顾与展望 被引量:4

Overview of measurement of femoral neck anteversion angle:History,current status and prospect
下载PDF
导出
摘要 股骨颈前倾角对于髋关节的力学传导及髋关节的正常活动有着重要意义。随着CT三维重建技术及计算机辅助设计技术的出现,已经能够从三维角度精确测量前倾角。但现有方法存在一定的不足,限制了其在临床中的广泛应用。而随着计算机技术的发展及混合虚拟现实技术的出现,实现前倾角的自动化精确测量和术中可视化已不再是难题,并将成为今后研究与临床应用的主流。 Femoral neck anteversion angle is important for the mechanical conduction and the normal movement of the hip joint.With the advent of CT three-dimensional reconstruction technology and computer-aided design technology,the anteversion angle can be measured accurately.However,the existing methods still have some disadvantages,which limit their wide application in clinical practice.With the development of computer technology and the emergence of hybrid virtual reality technology,the automated accurate measurement and intraoperative visualization of the anteversion angle is no longer a problem,and will become the mainstream in future research and clinical applications.
作者 徐高翔 唐佩福 XU Gaoxiang;TANG Peifu(Department of Orthopedics,the First Medical Center,Chinese PLA General Hospital,Beijing 100853,China)
出处 《解放军医学院学报》 CAS 2020年第1期97-100,共4页 Academic Journal of Chinese PLA Medical School
基金 首都卫生发展科研专项项目(2016-1-5012).
关键词 股骨颈前倾角 测量 CT三维重建 femoral neck anteversion angle measurement CT three-dimensional reconstruction
  • 相关文献

参考文献6

二级参考文献64

  • 1陆晴友,吴岳嵩,王成焘.股骨近端解剖形态的CT三维重建与分析[J].第二军医大学学报,2005,26(9):1029-1033. 被引量:37
  • 2Thielemann F, Schneider A, KShler T, et al. Long-term management results of Pemberton's Ilium osteotomy in combination with inter- trochanter derotation-varisation osteotomy in hip dysplasia of childhood [ J ] . Z Orthop Ihre Grenzgeb, 2003, 141 ( 4 ) : 459-464.
  • 3Hau R, Dickens DR, Nattrass GR, et al. Which implant for proximal femoral osteotomy in children? A comparison of the AO ( ASIF ) 90 degree fixed-angle blade plate and the Richards intermediate hip screw [ J ] . J Pediatr Orthop, 20 ( 3 ) : 336-343.
  • 4Enoksen CH, Gjerdet NR, Klaksvik J, et aL Initial stability of an uncemented femoral stem with modular necks. An experimental study in human cadaver femurs I J ]. Clin Biomech, 2014, 29(3): 330-335.
  • 5Gill IP, Webb J, Sloan K, et aL Corrosion at the neck- stem junction as a cause of metal ion release and pseudo- tumour formation [ J 1. J Bone Joint Surg, 2012, 94 (7) : 895 -900.
  • 6Bargar WL. Shape the implant to the patient. A rationale for the use of custom-fit cementless total hip implants [ J ]- C~in Orthop Re,at Res, 1989, 249: 73-78.
  • 7Sakai T, Sugano N, Nishii T, et aL Stem length and canal filling in uncemented custom-made total hip arthroplasty IJl. InterOrthop, 1999, 23(4): 219-223.
  • 8Noble PC, Alexander JW, Lindahl L J, et aL The anatomic basis of femoral component design [ Jl. Clin Othop Relat Res, 1988, 235: 148-165.
  • 9Laine H J, Kontola K, Lehto MUK, et al. Image processing for femoral endosteal anatomy detection: Description and testing of a computed tomography based program [ J 1. Phys Med Biol, 1997, 42(4) : 673-689.
  • 10Rubin P J, Leyvraz PF, Aubaniac JM, et aL The morpholo- gy of the proximal femur. A three-dimensional radiographic analysis [J~. J Bone Joint Surg, 1992, 74(1): 28-32.

共引文献77

同被引文献45

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部