摘要
文中设计了单面叠合剪力墙的钢筋连接件和不锈钢连接件,对不同端部构造形式的连接件进行单侧轴向拉拔试验。对其抗拔承载力、承载力-滑移曲线等进行分析,结果表明,破坏模式以混凝土锥形体被拔出为主,金属连接件的抗拔承载力均在16.92 kN以上。对金属连接件的抗拔承载力进行了计算,对比得出抗拔承载力试验值为计算值的0.92~3.17倍。
In this paper,the steel bar connectors and stainless steel connectors of single-sided superimposed shear wall are designed,and the single-sided axial pull-out test is carried out on the connectors with different end anchoring structures.The pull-bearing capacity and loaddisplacement curve are analyzed.The results show that the failure mode of the specimens is mainly the extraction failure of the concrete cone.The pull-bearing capacity of the metal connector is above 16.92 kN.The pull-out bearing capacity of the metal connector was calculated by formula.The results show that he test value of the pull-out bearing capacity was within the range of 0.92~3.17 times the calculated value.
作者
徐振华
徐海东
王朝辉
许笑林
Xu Zhenhua;Xu Haidong;Wang Zhaohui;Xu Xiaolin(College of Civil and Architectural Engineering,North China University of Science and Technology,Tangshan,Hebei 063210;Earthquake Engineering Research Center of Hebei Province,Tangshan,Hebei 063009)
出处
《江西建材》
2023年第6期348-350,共3页
Jiangxi Building Materials
关键词
单面叠合剪力墙
钢筋连接件
不锈钢连接件
拉拔性能
Single-sided superimposed shear wall
Steel bar connectors
Stainless steel connector
Pull-out performance